Mounting Scrape Cylinders - Vertical Votator Ii; Hydraulic System - Vertical Votator Ii; Check And Adjust Hydraulic Cylinder; Fill Hydraulic Reservoir - SPX Votator II Instruction Manual

Scraped surface heat exchanger
Table of Contents

Advertisement

Waukesha Cherry-Burrell
Mounting Scrape
Cylinders - Vertical
Votator II
Hydraulic System - Vertical
Votator II
Figure 18- Removal of Reservoir
11/2012
Using a crane or other lift device, lift cylinder from pedestal (drive)
end. Lifting in any other manner may damage cylinder.
Secure scrape cylinders in place with four (4) stainless steel 5/8-
inch bolts and lock washers provided. Maintain minimum distance
between protective cap and floor. See "Clearances" on page 9.
The Vertical Votator II is furnished with a hydraulic cylinder,
pump, motor, and fluid reservoir for removing and installing the
mutator shaft and heat transfer tube.
Check all fittings and adjustments prior to use; vibrations during
shipment may cause them to loosen.

Check and Adjust Hydraulic Cylinder

After heat exchanger cylinders are mounted to the pole, check to
ensure the proper distance is maintained between the bottom of
the hydraulic cylinder and the floor. See "Vertical Mounting Pole/
Hydraulics" on page 32.

Fill Hydraulic Reservoir

The system is pre-piped, but requires approximately two (2)
gallons of Dexron II ATF (ISO VG 32/68) to be added before use.
Please consult the factory if it is necessary to substitute fluids.
CAUTION: Do not mix fluid types.
Mixing fluids will damage equipment.
Remove reservoir from pump assembly and fill to opening for
return line. Reservoir is sealed with an O-ring and secured by a
clamp ring (See Figure 18, Item A). Pump return line (Figure 18,
item B) must be removed to access the reservoir.