Media System Check; Special Considerations For Vertical Votator Ii; Minimum Height - Vertical Votator Ii; Mounting Pole - Vertical Votator Ii - SPX Votator II Instruction Manual

Scraped surface heat exchanger
Table of Contents

Advertisement

Installation

Media System Check

Special Considerations for
Vertical Votator II
Minimum Height - Vertical
Votator II
Mounting Pole - Vertical
Votator II
Figure 17 - Mounting Disk
Page 24
Waukesha Cherry-Burrell
DANGER: Refrigeration controls should be operated and
serviced only by trained and qualified personnel.
Each cylinder is tested for leaks at the factory. However,
vibrations and handling during shipping can loosen piping
connections. Before starting a new unit, the system should be
checked for media leaks at the Votator II cylinder, the media
connections, and the piping to the cylinder using the following
procedures:
On units jacketed for steam or liquids, follow steps 1 through 6,
and then drain condensate from cylinder.
On units jacketed for refrigeration, follow steps 1 through 6, and
then pump down to remove refrigerant.
1. If a media pressure gauge is not installed in system, install
one at the media inlet of cylinder before processing.
2. Close off media return line from unit.
3. Open media inlet valve and let pressure increase to 5 psig,
then close valve.
4. Check front, back, and all piping connections for leaks.
5. If leaks are not detected, open inlet valve and let system
pressurize to 40 to 50 psig, then close valve.
6. Check again for leaks at front, back, and all piping
connections.
The customer is responsible for securing the top and bottom of
the pole and scrape assembly. See "Votator II Vertical Mounting
Suggestions" in Addendum Section.
The mounting pole with hydraulic components is assembled at
the factory to provide the proper height from the floor when
installed. Therefore, never trim the pole from the bottom.
Check to be sure the cylinders will be positioned with minimum
clearance to insure shaft can be removed correctly. See
"Clearances" on page 9.
Attach post mount to floor. (Stainless steel disk which serves as
base for pole.) There is a 13/16" diameter hole through the center
of the disk for mounting it to the floor. Make sure post mount is
level after installation.
Prepare site for attaching top of pole. Top of pole can be trimmed
if needed.
NOTE: When installing pole, make sure hydraulic cylinder faces
toward same side scrape cylinders will be mounted on.
Put bottom of pole over post mount and raise.
Attach top of pole to top mounting.
NOTE: Pole MUST be vertical and plumb.
95-03057
11/2012

Hide quick links:

Advertisement

Table of Contents
loading