Table A-16 Pll Characteristics - Motorola MC9S12DT256 User Manual

Table of Contents

Advertisement

MC9S12DT256 Device User Guide — V03.07
This is very important to notice with respect to timers, serial modules where a pre-scaler will eliminate the
effect of the jitter to a large extent.
Conditions are shown in Table A-4 unless otherwise noted
Num C
1
P Self Clock Mode frequency
2
D VCO locking range
Lock Detector transition from Acquisition to Tracking
3
D
mode
4
D Lock Detection
5
D Un-Lock Detection
Lock Detector transition from Tracking to Acquisition
6
D
mode
7
C PLLON Total Stabilization delay (Auto Mode)
8
D PLLON Acquisition mode stabilization delay
9
D PLLON Tracking mode stabilization delay
10
D Fitting parameter VCO loop gain
11
D Fitting parameter VCO loop frequency
12
D Charge pump current acquisition mode
13
D Charge pump current tracking mode
14
C Jitter fit parameter 1
15
C Jitter fit parameter 2
NOTES:
1. % deviation from target frequency
2. f
= 4MHz, f
= 25MHz equivalent f
osc
BUS
116

Table A-16 PLL Characteristics

Rating
2
(2)
(2)
(2)
(2)
= 50MHz: REFDV = #$03, SYNR = #$018, Cs = 4.7nF, Cp = 470pF, Rs = 10K
VCO
Symbol
Min
f
1
SCM
f
8
VCO
|∆
|
3
trk
|∆
|
0
Lock
|∆
|
0.5
unl
|∆
|
6
unt
t
stab
t
acq
t
al
K
1
f
1
| i
|
ch
| i
|
ch
j
1
j
2
Typ
Max
Unit
5.5
MHz
50
MHz
4
%
1.5
%
2.5
%
8
%
0.5
ms
0.3
ms
0.2
ms
-100
MHz/V
60
MHz
µA
38.5
µA
3.5
1.1
0.13
1
(1)
(1)
(1)
%
%
.