Item
Protect V-VOLs when I/O fails to
Blocked Pool VOL
Protect V-VOLs when I/O fails to Full
Pool
Number of Pool VOLs
Tier Management
Cycle Time
Monitoring Period
Monitoring Mode
Relocation speed
Buffer Space for New page
assignment (%)
Buffer Space for Tier relocation (%)
320 Thin Provisioning and Smart Tiers GUI reference
Description
Displays whether the protect function for THP V-VOL is being enabled or disabled.
If the setting is enabled, when the pool-VOL is blocked, THP V-VOL is protected
from reading and writing requests. And at the same instant, the access attribute
of the THP V-VOL is changed to the Protect attribute.
A hyphen appears if the pool corresponds with one of following:
Data Retention is not installed.
Pool type is the type other than THP or Smart.
Displays whether the protect function for THP V-VOL is being enabled or disabled.
If the setting is enabled, when the pool usage reaches the full size, THP V-VOL
is protected from reading and writing requests. And at the same instant, the
access attribute of the THP V-VOL is changed to the Protect attribute.
A hyphen appears if the pool corresponds with one of following:
Data Retention is not installed.
Pool type is other than THP or Smart.
Displays the number of pool-VOLs.
If Smart Tiers or Smart Tiers Z is enabled, Auto or Manual for performance
monitoring and tier relocation is displayed. If Smart Tiers or Smart Tiers Z is
disabled, a hyphen (-) is displayed.
Displays the cycle of performance monitoring and tier relocation. If Smart Tiers
or Smart Tiers Z is disabled, a hyphen (-) is displayed.
Displays the time zone of performance monitoring when 24 Hours is selected
as the Cycle Time. If Smart Tiers or Smart Tiers Z is disabled, a hyphen (-) is
displayed.
If the continuous mode is enabled, Continuous Mode is displayed. If the period
mode is enabled, Period Mode is displayed.
Displays the page relocation speed: 1(Slowest), 2(Slower), 3(Standard), 4(Faster),
or 5(Fastest). If Smart Tiers or Smart Tiers Z is disabled, a hyphen (-) is displayed.
Displays the information of the buffer space for new page assignment to each
tier.
Tier 1: If you make the Smart Tiers or Smart Tiers Z function available, the buffer
space for new page assignment to tier 1 is displayed. If you make the Smart
Tiers or Smart Tiers Z function unavailable, a hyphen (-) is displayed.
Tier 2: If you make the Smart Tiers or Smart Tiers Z function available, and tier
2 exists, the buffer space for new page assignment to tier 2 is displayed. If you
make the Smart Tiers or Smart Tiers Z function unavailable, or tier 2 does not
exist, a hyphen (-) is displayed.
Tier 3: If you make the Smart Tiers or Smart Tiers Z function available, and tier
3 exists, the buffer space for new page assignment to tier 3 is displayed. If you
make the Smart Tiers or Smart Tiers Z function unavailable, or tier 3 does not
exist, a hyphen (-) is displayed.
Displays the information of the buffer space for tier relocation to each tier.
Tier 1: If you make the Smart Tiers or Smart Tiers Z function available, the buffer
space for tier relocation to tier 1 is displayed. If you make the Smart Tiers or
Smart Tiers Z function unavailable, a hyphen (-) is displayed.
Tier 2: If you make the Smart Tiers or Smart Tiers Z function available, and tier
2 exists, the buffer space for tier relocation to tier 2 is displayed. If you make
the Smart Tiers or Smart Tiers Z function unavailable, or tier 2 does not exist, a
hyphen (-) is displayed.
Tier 3: If you make the Smart Tiers or Smart Tiers Z function available, and tier
3 exists, the buffer space for tier relocation to tier 3 is displayed. If you make
the Smart Tiers or Smart Tiers Z function unavailable, or tier 3 does not exist, a
hyphen (-) is displayed.