(V)PE-...-...(SW )
Product-specific specifications (V)PE-...-SW (cable types)
Typ
Part no.
Operating pressure
Switch-on point
Switch-off point
Overload pressure
(brief, static)
Rated operating
voltage (V
)
b
Rated operating cur­
rent (with V
)
b
Use category
Switching output
(DC voltage)
Protection class
Materials
– Housing
– Connections
– Diaphragm
– Switching contact
Fig. 19
12
PE-PK-4-SW
7471
[bar]
0 ... 0,25
[bar]
≤ 0,25
[bar]
≥ 0,07
[bar]
max. 8
[V]
AC/DC 250
[A]
– ohmic load
[A]
– induktive Last
– ohmic load
– small electromagnetic load
Voltage [V DC]:
[A]
– resistor load
[A]
– Induktive Last
[A]
– bulb load
(as per EN 60 529) IP67
POM/PA/St/VMQ
CR
PVC
Ag
PE-1/8-
PE-1/8-
1N-SW
2N-SW
6484
7862
0 ... 8
≤ 2
≥ 0,5
bei AC 250 V
bei DC 250 V
5
0,25
2
0,03
AC 12/DC 12
AC 14/DC 13
15
30
50
75
10
5
1
0,75
10
3
1
0,25
3
3
0,7
0,5
PA/GD-AL/St/VMQ
TPE-U-(PU)
PVC
Ag
Festo (V)PE-...-...(SW) 2017-05c English
VPE-
VPE-1/8-
1/8-SW
2N-SW
12593
12595
0 ... -0,95
-0,25  0,05
≤ -0,1
max. 1
125
250
0,5
0,25
0,03
0,02
0,4
0,20
POM/PA/VMQ/St
CR
PVC
Ag