Festo VPE-1/8 Operating Instructions Manual page 11

Pressure/vacuum switch
Table of Contents

Advertisement

(V)PE-...-...(SW )
Type
Maximum switching frequency
CE marking symbol (see conformity declaration)
Fig. 17
Product-specific specifications (V)PE-... without (V)PE-....-SW
Typ
Part no.
Operating pressure
Switch-on point
Switch-off point
Overload pressure
(brief, static)
Rated operating
voltage (V
)
b
Rated operating cur­
rent (with V
)
b
Use category
Switching output
(DC voltage)
Protection class
Materials
– Housing
– Connections
– Diaphragm
– Switching contact
Fig. 18
Festo (V)PE-...-...(SW) 2017-05c English
[Hz]
PE-PK-4
7470
[bar]
0 ... 0,25
[bar]
≤ 0,08
[bar]
≥ 0,01
[bar]
max. 8
[V]
AC/DC 250
[A]
– ohmic load
[A]
– inductive load
– ohmic load
– small electromagnetic load
Voltage [V DC]:
[A]
– resistor load
[A]
– inductive load
[A]
– bulb load
(as per EN 60 529) IP00, IP20 with protective cap type SPE-B
PET/POM/St
CuZn
CR
Ag
(V)PE-...
1
as per EU low voltage directive
PE-PK-
PE-
PE-
3x2-2N
1/8-1N
1/8-2N
13691
6217
7860
0 ... 8
≤ 2
≥ 0,5
max. 12
at AC 250 V
6
2
AC 12/DC 12
AC 14/DC 13
12
24
60
6
6
1
6
6
0,5
3
2
0,6
PA/GD-AL/St/PET
CuZn
TPE-U(PU)
Ag
VPE-
VPE-
1/8
1/8-2N
12592
12594
0 ... -0,95
-0,25  0,05
≤ -0,1
max. 1
at DC 250 V
0,25
0,1
110
220
0,5
0,25
0,2
0,1
0,5
0,25
PET/POM/St
CuZn
CR
Ag
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents