Page 1
® 2N Access Unit Access Control Installation manual Firmware: Version: 2.11 www.2n.cz...
Page 2
2N TELEKOMUNIKACE a.s. administers the FAQ database to help you quickly find information and to answer your questions about 2N products and services. On www. faq.2n.cz you can find information regarding products adjustment and instructions for optimum use and procedures „What to do if...".
Page 3
2.2.2 Two Module Box 2.2.3 Module dimensions 2.3 Electric Installation 2.4 Extending Module Connection 2.5 Mounting Completion 3. Maintenance 4. Technical Parameters 5. Supplementary Information 5.1 Troubleshooting 5.2 Directives, Laws and Regulations 5.3 General Instructions and Cautions 2N TELEKOMUNIKACE a.s., www.2n.cz 3/98...
1. Product Overview Here is what you can find in this section: 1.1 Components and Associated Products 1.2 Terms and Symbols 2N TELEKOMUNIKACE a.s., www.2n.cz 4/98...
12 V power supply or directly from your PoE-supporting LAN. ® To configure 2N Access Unit , you need a PC equipped with any Internet browser. To ® manage extensive intercom installations easily, use the Access Commander 2N TELEKOMUNIKACE a.s., www.2n.cz 5/98...
LAN (PoE) or external 12 V power supply Configuration via web interface HTTP server for configuration SNTP client for server time synchronisation SMTP client for e-mail sending TFTP/HTTP client for automatic configuration and firmware update 2N TELEKOMUNIKACE a.s., www.2n.cz 6/98...
1.1 Components and Associated Products Basic Units Part No. 916009 ® Access Unit 125 kHz Part No. 916010 ® Access Unit 13.56 MHz + NFC Part No. 916013 ® Access Unit Bluetooth 2N TELEKOMUNIKACE a.s., www.2n.cz 7/98...
Page 8
Part No. 916019 ® Access Unit Fingerprint reader ® Supported auxiliary modules: 2N Helios IP Verso modules are supported – RFID card reader (125 kHz; 13.56 MHz), keypad, 5-button module, Wiegand, etc. 2N TELEKOMUNIKACE a.s., www.2n.cz 8/98...
Page 9
1-module flush mounting box, Part No. 9155014. Part No. 9155012 Flush mounting frame, 2-module Covering frame for the 2-module brick/plasterboard flush mounting box. Remember to order the frame when you order a 2-module flush mounting box, Part No. 9155015. 2N TELEKOMUNIKACE a.s., www.2n.cz 9/98...
Page 10
OUT card reader or keypad, for example. Part No. 9155021B Wall mounting frame, 1-module Covering frame for wall (surface) mounting.This 1- module frame is used for connection of an OUT card reader or keypad, for example. 2N TELEKOMUNIKACE a.s., www.2n.cz 10/98...
Page 11
9155022B Wall mounting frame, 2-module Covering frame for wall (surface) mounting. ® The 1-module frame is used when an auxiliary module from 2N Helios IP Verso is mounted onto an extended interconnecting cable, for an OUT card reader or keypad, for example.
Page 12
Remember to order the flush mounting frame when you order a brick /plasterboard flush mounting box: 1-module frame, Part No. 9155011 – 1-module flush mounting box, Part No. 9155014 2-module frame, Part No. 9155012 – 2-module flush mounting box, Part No. 9155015 2N TELEKOMUNIKACE a.s., www.2n.cz 12/98...
– 125 kHz RFID Card Reader ® The card reader module works with Access Unit as an OUT card reader. The module supports cards, key fobs and/or other 125 kHz standard carriers: EM-41xx HID Proximity 2N TELEKOMUNIKACE a.s., www.2n.cz 13/98...
Page 14
– I/O Module The logic input/output module helps you integrate various sensors and control doors or other equipment. The module is installed under ® another module, i.e. cannot be installed directly into the 2N Access Unit (must be mounted outside).
Page 15
9155030 ® Helios IP Verso – Infopanel The Infopanel module helps you add your company logo, opening hours and similar information to the access unit. The Infopanel has software-controlled backlight. Part Numbers: 1 m Interconnecting Cable 155050 3 m Interconnecting Cable...
Supplied including accessories for multiple box assemblies. Part No. Backplate, 1 module 9155061 A backplate for glass or uneven surface mounting. Part No. Backplate, 2 modules 9155062 A backplate for glass or uneven surface mounting. 2N TELEKOMUNIKACE a.s., www.2n.cz 16/98...
Page 17
® For the Access Unit installation choose the appropriate mounting frame and box ® if necessary. The Access Unit is designed for outdoor applications and requires no additional roof. 2N TELEKOMUNIKACE a.s., www.2n.cz 17/98...
When closed, it behaves as standart electrical lock. Part No. 932061E 211211 door signalling, low consumption 12 V / 230 mA A regular lock with a built-in contact to indicate whether the door is open or closed. 2N TELEKOMUNIKACE a.s., www.2n.cz 18/98...
Page 19
The failsafe lock is closed when electricity is switched on. When electricity is interrupted, the lock is opened. It contains a built-in contact to indicate whether the door is open or closed. ® FAQ:Electric locks – Differences between locks for 2N Helios IP 2N TELEKOMUNIKACE a.s., www.2n.cz 19/98...
Part No. 91341481E Stabilised 12 V / 2 A power supply needs to be used when no PoE is available. Part No. 932928 For external power supply of the lock with 12 V AC voltage. 2N TELEKOMUNIKACE a.s., www.2n.cz 20/98...
Part No. 9159012 Magnetic door contact A door installation set for door opening status identification. Used for door protection, open door or violent door opening detection. Part No. 9134173 13.56 MHz Mifare RFID card 2N TELEKOMUNIKACE a.s., www.2n.cz 21/98...
Page 22
13.56 MHz and 125 kHz USB RFID card reader External RFID card reader for connection to PC using a USB interface. Suitable for system administration and adding of 13.56 MHz and 125 kHz cards using a web interface or the ® Access Commander 2N TELEKOMUNIKACE a.s., www.2n.cz 22/98...
Page 23
® 2Wire unit then provides supply not only to the other converter, but also to all the IP terminal equipment connected. 2N TELEKOMUNIKACE a.s., www.2n.cz 23/98...
Page 24
Secondary reader for connection to an internal reader. Allows for control of card entry from both sides of the door. IP68 cover, also suitable for exteriors. Reads Mifare cards. Refer to the local 2N distributor for more accessories and recommendations please. 2N TELEKOMUNIKACE a.s., www.2n.cz...
Warning Always abide by this information to prevent damage to the device. Caution Important information for system functionality. Useful information for quick and efficient functionality. Note Routines or advice for efficient use of the device. 2N TELEKOMUNIKACE a.s., www.2n.cz 25/98...
2. Description and Installation Here is what you can find in this section: 2.1 Before You Start 2.2 Mechanical Installation 2.3 Electric Installation 2.4 Extending Module Connection 2.5 Mounting Completion 2N TELEKOMUNIKACE a.s., www.2n.cz 26/98...
When the proper mounting instructions are not met, water might get in and destroy the electronics. It is because the intercom circuits are under continuous voltage and water infiltration causes an electro-chemical reaction. The manufacturer’s warranty shall be void for products damaged in this way! 2N TELEKOMUNIKACE a.s., www.2n.cz 30/98...
You are advised to buy the flush mounting box in advance and commission a building company to do the masonry for you, for example. The mounting box also helps you put your intercom exactly in the vertical position. 2N TELEKOMUNIKACE a.s., www.2n.cz 31/98...
Page 32
The wall mounting surface must be flat with the maximum inequality of 0.5 mm (e.g. prefabricated boards, glass, cut stone, etc.). If the surface is uneven, use flush mounting and a backplate, Part Nos. 9155061 9155062 – or equalise the wall surface. 2N TELEKOMUNIKACE a.s., www.2n.cz 32/98...
The manufacturer shall not be liable for injuries in such cases! Module Installation 2.2.1 One Module Box 2.2.2 Two Module Box 2.2.3 Module dimensions 2N TELEKOMUNIKACE a.s., www.2n.cz 33/98...
Pull the Ethernet cable through the bottom hole to the left if necessary. Insert the metal fitting elements up and down and screw the access unit tight. You can level the unit slightly in this mounting type.
(Cat 5e or higher) terminated with a terminal board as shown in the figure below. As the device is equipped with the Auto-MDIX function, either the straight or crossed cable can be used. Caution We recommend the use of a LAN surge protection. 2N TELEKOMUNIKACE a.s., www.2n.cz 68/98...
PoE phantom supply (typically TP-LINK) to spare-pair supply – Phihong injector, Part No. 91378100 change the Ethernet bitrate to Half Duplex – 10 mbps UTP Cable Connection to Access Unit Terminal Board Legend to the figure PoE, LAN (PoE according to 802.1af) terminals...
Wiring diagram of IN1, IN2 and IN3 terminals in active mode Wiring diagram of IN1, IN2 and IN3 terminals in passive mode Device Restart Press the RESET button (between the LED indicators in the right-hand upper part) shortly to restart the device. Factory Reset 2N TELEKOMUNIKACE a.s., www.2n.cz 70/98...
Page 71
The button is located in the middle of the lower part in version 586v4 Press the button shortly (< 1 s) to restart the system without changing configuration. ® Access Unit Connectors, PCB Version 586v2 2N TELEKOMUNIKACE a.s., www.2n.cz 71/98...
Page 72
Press and hold the RESET button. Wait untilthe red and green LEDs in the right-hand bottom part of the motherboard shine simultaneously (approx. 20 s). Wait until the red LED goes off (approx. 5 s). Release the RESET button. 2N TELEKOMUNIKACE a.s., www.2n.cz 72/98...
Page 73
Wait until the red LED goes off (approx. 5 s). Wait until the green LED goes off and the red LED comes on again (another 5 s). Wait until the red LED goes off (approx. 5 s). Release the RESET button. 2N TELEKOMUNIKACE a.s., www.2n.cz 73/98...
For this way of protection we recommend a 1 A / 1000 V diode (e.g., 1N4007, 1N5407, 1N5408) connected antiparallel to the device. 2N TELEKOMUNIKACE a.s., www.2n.cz 74/98...
These two modules can be hidden inside one of the modules described below (Infopanel, Keypad, RFID card reader, Bluetooth) and/or placed freely behind a standalone access unit (in a mounting box, e.g.). You can order a separate bus cable ( Part Nos.
If this module is the last one on the bus, one of the connectors remains unconnected. The module package includes a 220 mm long interconnecting cable. 2N TELEKOMUNIKACE a.s., www.2n.cz 77/98...
Page 78
The following RFID cards can be read (only card serial number is read): ISO 14443A Mifare Classic 1k & 4k, DESFire EV1, Mini, Plus S&X, Ultralight, Ultralight C ISO 14443B CEPAS, HID iCLASS JIS X 6319 Felica 2N TELEKOMUNIKACE a.s., www.2n.cz 78/98...
The module package includes a 220 mm long interconnecting cable. Important module properties: FBI PIV and Mobile ID certification – FAP20 Durable glass touch surface Rejects spoof fingerprints -20 to 55 ºC operating temperature range, 0–90% relative humidity, noncondensing I/O Module 2N TELEKOMUNIKACE a.s., www.2n.cz 79/98...
Page 80
RELAY2 terminals with accessible 30 V / 1 A AC/DC NO/NC contact IN1 terminals for input in passive/ active mode (−30 V to +30 V DC) OFF = open or U > 1.5 V ON = short-circuit or U < 1.5 V 2N TELEKOMUNIKACE a.s., www.2n.cz 80/98...
The Wiegand module ( Part No. 9155037 ) helps connect an external Wiegand device ® (RFID card reader, fingerprint or other biometric data reader) and/or connect 2N Access Unit to an external security exchange. All the inputs and outputs are ®...
Page 82
Isolated input for open LED IN, input activated by GND LEDIN Isolated input for open LED IN, input activated by +U active supply LED indicator +U WIEGAND OUT TAMPER Tamper switch input, Part No. 9155038 Security Relay 2N TELEKOMUNIKACE a.s., www.2n.cz 82/98...
(inside the secured area). The Security relay includes a relay that can only be activated if the valid opening code is received from the access unit. Specifications: Passive switch: NO and NC contacts, up to 30 V / 1 A AC / DC Active switch output: 9 to 13 V DC according to power source (PoE: 9 V;...
Programming mode – waiting for initialisation flashing Error – wrong code received Configuration: Connect the Security relay to the properly set access unit security output. For ® settings refer to the Access Unit Configuration Manual is installed. Make sure that one LED at least is on or flashing.
Page 85
® ® FAQ: 2N Helios IP Security Relay device description and use with 2N Helios IP ® Video Tutorial Door intercoms 2N Helios IP – Security Relay Connection: 2N TELEKOMUNIKACE a.s., www.2n.cz 85/98...
Make sure that all the holes are filled with some waterproof material – the top part, around the cables and the screws. Use silicone or some other sealant to seal the box against the wall if uneven to avoid water leakage and wall damping. 2N TELEKOMUNIKACE a.s., www.2n.cz 86/98...
Make sure that the bases are levelled properly to avoid water leakage and electronic damage. The examples in the figures below show incorrectly assembled bases. This happens, in particular, where the screws are tightened first. 2N TELEKOMUNIKACE a.s., www.2n.cz 87/98...
Page 89
Do not use aggressive detergents (such as abrasives or strong disinfectants). Clean the device in dry weather in order to make waste water evaporate quickly. Warning Prevent water from getting inside the access unit. Do not use Alcohol-based cleaners. 2N TELEKOMUNIKACE a.s., www.2n.cz...
ISO/IEC 14443A: Mifare Classic 1k & 4k, DESFire EV1, Mini, Plus S&X, Ultralight, Ultralight C ISO/IEC 14443B: CEPAS, HID iCLASS JIS X 6319: Felica ISO/IEC 18092: SmartPhone with NFC/HCE support, since Android version Supported 125 kHz cards: EM4100, EM4102, HID Prox 2N TELEKOMUNIKACE a.s., www.2n.cz 90/98...
Page 91
1 module: 108 (W) x 131 (H) x 45 (D) mm 2 modules: 108 (W) x 238 (H) x 45 (D) mm Weight: Max net weight: 2 kg / max gross weight: 0.5 kg – based on configuration Cover rating: IP54 2N TELEKOMUNIKACE a.s., www.2n.cz 91/98...
5. Supplementary Information Here is what you can find in this section: 5.1 Troubleshooting 5.2 Directives, Laws and Regulations 5.3 General Instructions and Cautions 2N TELEKOMUNIKACE a.s., www.2n.cz 92/98...
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. 2N TELEKOMUNIKACE a.s., www.2n.cz 94/98...
Page 95
Consult the dealer or an experienced radio/TV technician for help. Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. 2N TELEKOMUNIKACE a.s., www.2n.cz 95/98...
The consumer shall, at its own expense, obtain software protection of the product. The manufacturer shall not be held liable and responsible for any damage incurred as a result of the use of deficient or substandard security software. 2N TELEKOMUNIKACE a.s., www.2n.cz 96/98...
Make sure that the devices to be disposed of are complete. Do not throw battery packs into fire. Battery packs may not be taken into parts or short-circuited either. 2N TELEKOMUNIKACE a.s., www.2n.cz 97/98...