  • Page 1 Access Unit Access Control Installation manual Version: 2.13 www.2n.cz...
  • Page 2 2N TELEKOMUNIKACE a.s. administers the FAQ database to help you quickly find information and to answer your questions about 2N products and services. On www. faq.2n.cz you can find information regarding products adjustment and instructions for optimum use and procedures „What to do if...".
  • Page 3: Table Of Contents

    2.2.2 Two Module Box 2.2.3 Module dimensions 2.3 Electric Installation 2.4 Extending Module Connection 2.5 Mounting Completion 3. Maintenance 4. Technical Parameters 5. Supplementary Information 5.1 Troubleshooting 5.2 Directives, Laws and Regulations 5.3 General Instructions and Cautions 2N TELEKOMUNIKACE a.s., www.2n.cz 3/116...
  • Page 4: Product Overview

    1. Product Overview Here is what you can find in this section: 1.1 Components and Associated Products 1.2 Terms and Symbols 2N TELEKOMUNIKACE a.s., www.2n.cz 4/116...
  • Page 5 Basic Properties 2N Access Unit is an elegant and reliable access IP system equipped with a number of useful functions, which are not always common in devices of this category. 2N Access Unit is a modular access system that meets all individual user needs. Unlike...
  • Page 6 LAN (PoE) or external 12 V power supply Configuration via web interface HTTP server for configuration SNTP client for server time synchronisation SMTP client for e-mail sending TFTP/HTTP client for automatic configuration and firmware update 2N TELEKOMUNIKACE a.s., www.2n.cz 6/116...
  • Page 7: Components And Associated Products

    1.1 Components and Associated Products Basic Units 2N Part No. 916009 ® Access Unit 125kHz Axis Part No. 01365-001 The card reader provides you with access control via contactless cards or keyfobs. The module supports the 125 kHz EM-41xx or HID Proximity cards.
  • Page 8 Part No. 9160334 ® Access Unit 2.0 RFID – 125kHz, 13.56MHz, NFC The card reader provides you with access control via contactless cards or keyfobs. The module supports the 125 kHz EM-41xx or HID Proximity cards.
  • Page 9 SE, SEOS) Part No. 9160335 ® Access Unit 2.0 Bluetooth & RFID – 125kHz, 13.56MHz, The bluetooth card reader module provides you with access control via contactless cards or keyfobs. The module supports the following 125 kHz and 13.56 MHz...
  • Page 10 SRI4K, SRIX4K, PicoPass, HID iCLASS (also PACS ID from SE, SEOS) Part No. 9160336 ® Access Unit 2.0 Touch keypad & RFID – 125kHz, 13.56 MHz, NFC The touch keypad and card reader module provides you with access control via contactless cards or keyfobs. The module supports the following 125 kHz and 13.56 MHz...
  • Page 11 Part No. 9160336-S ® Access Unit 2.0 Touch keypad & RFID – 125kHz, Axis Part No. 01852-001 secured 13.56MHz, NFC The touch keypad and card reader module provides you with access control via contactless cards or keyfobs. The module supports the following 125 kHz and 13.56 MHz...
  • Page 12 2N Part No. 9155012 Flush mounting frame, 2-module Axis Part No. 01281-001 Covering frame for the 2-module brick/plasterboard flush mounting box. Remember to order the frame when you order a 2-module flush mounting box, Part No. 9155015. 2N TELEKOMUNIKACE a.s., www.2n.cz 12/116...
  • Page 13 2N Part No. 9155021B Wall mounting frame, 1-module Axis Part No. 01288-001 Covering frame for wall (surface) mounting.This 1-module frame is used for connection of an OUT card reader or keypad, for example. 2N TELEKOMUNIKACE a.s., www.2n.cz 13/116...
  • Page 14 Axis Part No. 01290-001 Covering frame for wall (surface) mounting. ® The 1-module frame is used when an auxiliary module from 2N IP Verso is mounted onto an extended interconnecting cable, for an OUT card reader or keypad, for example.
  • Page 15 Remember to order the flush mounting frame when you order a brick /plasterboard flush mounting box: 1-module frame, Part No. 9155011 – 1-module flush mounting box, Part No. 9155014 2-module frame, Part No. 9155012 – 2-module flush mounting box, Part No. 9155015 2N TELEKOMUNIKACE a.s., www.2n.cz 15/116...
  • Page 16 Extending Modules 2N Part No. 916020 RJ-45 adapter Axis Part No. 01371-001 2N Part No. 9155033 ® IP Verso – RFID Reader, 13.56 MHz Axis Part No. 01256-001 The card reader module works with 2N Access Unit as an OUT card reader. The module supports cards, key fobs and/or other 13.56 MHz standard...
  • Page 17 Part No. 9155082 ® IP Verso – Bluetooth & RFID reader 125kHz, 13.56MHz, The bluetooth and card reader module works with 2N Access Unit as an OUT card reader. The module supports cards, key fobs and/or other 125 kHz and 13.56 MHz standard carriers (only card serial number is read): ®...
  • Page 18 IP Verso – Touch keypad & RFID reader 125kHz, 13.56 MHz, NFC The touch keypad and card reader module works with 2N Access Unit as an OUT card reader. The module supports cards, key fobs and/or other 125 kHz and 13.56 MHz standard carriers (only card serial number is read): ®...
  • Page 19 13.56MHz, NFC The touch keypad and secured card reader module works with 2N Access Unit as an OUT card reader. The module supports cards, key fobs and/or other 125 kHz and 13.56 MHz standard carriers (only card serial number is read): ®...
  • Page 20 2N Part No. 9155030 ® IP Verso – Info panel Axis Part No. 01252-001 The Infopanel module helps you add your company logo, opening hours and similar information to the access unit. The Infopanel has software-controlled backlight. 2N TELEKOMUNIKACE a.s., www.2n.cz 20/116...
  • Page 21 Part Numbers: 1 m Interconnecting Cable 155050, 01267-001 3 m Interconnecting Cable 5 m Interconnecting Cable 9155054, 01268-001 9155055, 01269-001 2N TELEKOMUNIKACE a.s., www.2n.cz 21/116...
  • Page 22 Axis Part No. 01285- The box is designed for brick/plasterboard flush mounting of a 2- module installation. Supplied including accessories for multiple box assemblies. 2N Part No. 9155061 Backplate, 1 module Axis Part No. A backplate for glass or uneven surface mounting.
  • Page 23 9155062 A backplate for glass or uneven surface mounting. Axis Part No. 01294-001 For the 2N Access Unit installation choose the appropriate mounting frame and box if necessary. The 2N Access Unit is designed for outdoor applications and requires no additional roof.
  • Page 24 When closed, it behaves as standart electrical lock. Part No. 932061E 211211 door signalling, low consumption 12 V / 230 mA A regular lock with a built-in contact to indicate whether the door is open or closed. 2N TELEKOMUNIKACE a.s., www.2n.cz 24/116...
  • Page 25 The failsafe lock is closed when electricity is switched on. When electricity is interrupted, the lock is opened. It contains a built-in contact to indicate whether the door is open or closed. FAQ: Electric locks – Differences between locks for 2N IP intercoms 2N TELEKOMUNIKACE a.s., www.2n.cz 25/116...
  • Page 26 Part No. Stabilised 12 V / 1 A power supply needs to be used when no PoE is available. 91341482E 91341482US Part No. 932928 For external power supply of the lock with 12 V AC voltage. 2N TELEKOMUNIKACE a.s., www.2n.cz 26/116...
  • Page 27 Part No. 9159013 Departure button Connects the logic input for door unlocking from inside the building. 2N Part No. 9159012 Magnetic door contact Axis Part No. 01388-001 A door installation set for door opening status identification. Used for door protection, open door or violent door opening detection.
  • Page 28 External RFID card reader for connection to PC using a USB interface. Axis Part No. 01399-001 Suitable for system administration and adding of 125 ® kHz EM41xx cards using a web interface or the 2N Access Commander 2N TELEKOMUNIKACE a.s., www.2n.cz 28/116...
  • Page 29 External RFID card reader for connection to PC using a USB interface. Suitable for system administration and adding 13.56 MHz, 125 kHz cards and Android platform devices supporting NFC/HCE using 2N IP intercom ® web interface or the 2N Access Commander application.
  • Page 30 Ultralight C 13.56 MHz/ISO/IEC 14443B CEPAS, HID iCLASS (CSN or PAC ID) 13.56 MHz/JIS X 6319 Felica ISO/IEC 18092 SmartPhone with NFC/HCE ® support, since Android version 4.3 (2N Mobile app required) EMarine 2N Part No. 9137423E ® IP intercom - external fingerprint reader (USB Axis Part No.
  • Page 31 2N Part No. 9137411E External IP relay – 4 outputs, PoE Axis Part No. 01398-001 A stand-alone IP device, which can be controlled from an IP intercom via HTTP commands. Helps control a device remotely. 2N TELEKOMUNIKACE a.s., www.2n.cz 31/116...
  • Page 32 IP terminal equipment connected. 2N Part No. 9159030 External 125 kHz RFID card reader Axis Part No. 01389-001 Secondary reader for connection to an internal reader.
  • Page 33 Secondary reader for connection to an internal reader. Allows for control of card entry from both sides of the door. IP68 cover, also suitable for exteriors. Reads Mifare cards. Refer to the local 2N distributor for more accessories and recommendations please. 2N TELEKOMUNIKACE a.s., www.2n.cz 33/116...
  • Page 34: Terms And Symbols

    Warning Always abide by this information to prevent damage to the device. Caution Important information for system functionality. Useful information for quick and efficient functionality. Note Routines or advice for efficient use of the device. 2N TELEKOMUNIKACE a.s., www.2n.cz 34/116...
  • Page 35: Description And Installation

    2. Description and Installation Here is what you can find in this section: 2.1 Before You Start 2.2 Mechanical Installation 2.3 Electric Installation 2.4 Extending Module Connection 2.5 Mounting Completion 2N TELEKOMUNIKACE a.s., www.2n.cz 35/116...
  • Page 36: Before You Start

    2.1 Before You Start Product Completeness Check Check your 2N Access Unit package for completeness before installation. 1x 2N Access Unit 1x Hex key Brief manual 2N TELEKOMUNIKACE a.s., www.2n.cz 36/116...
  • Page 37: Mechanical Installation

    What you need for mounting: a properly cut hole as instructed in the box package plaster, mounting glue, mounting foam or mortar as necessary 2N Access Unit flush mounting box and frame 1 module: box Part No. 9155014 , frame part No.
  • Page 38 Flush mounting – plasterboard What you need for mounting: a properly cut hole as instructed in the box package 2N Access Unit flush mounting box and frame 1 module: box Part No. 9155014 , frame part No. 9155011 2 modules: box Part No.
  • Page 39 Wall (surface) mounting (concrete and steel structures, entry barrier columns, interiors, etc.) What you need for mounting: 2N Access Unit a proper frame 1 module: frame Part No. 9155021 2 modules: frame Part No. 9155022 For uneven surfaces use a backplate for the required count of modules, Part Nos.
  • Page 40 You are advised to buy the flush mounting box in advance and commission a building company to do the masonry for you, for example. The mounting box also helps you put your intercom exactly in the vertical position. 2N TELEKOMUNIKACE a.s., www.2n.cz 40/116...
  • Page 41 Having removed the front panel, make sure that no dirt gets inside the product (especially onto the sealing surface). Never turn an assembly of 2N Access Unit devices after mounting. Make sure that the flush mounting boxes have been installed accurately.
  • Page 42 The manufacturer shall not be liable for injuries in such cases! Module Installation 2.2.1 One Module Box 2.2.2 Two Module Box 2.2.3 Module dimensions 2N TELEKOMUNIKACE a.s., www.2n.cz 42/116...
  • Page 43: One Module Box

    2.2.1 One Module Box Flush mounting – classic bricks 2N TELEKOMUNIKACE a.s., www.2n.cz 43/116...
  • Page 44 2N TELEKOMUNIKACE a.s., www.2n.cz 44/116...
  • Page 45 Flush mounting – plasterboard 2N TELEKOMUNIKACE a.s., www.2n.cz 45/116...
  • Page 46 2N TELEKOMUNIKACE a.s., www.2n.cz 46/116...
  • Page 47 2N TELEKOMUNIKACE a.s., www.2n.cz 47/116...
  • Page 48 Module flush mounting 2N TELEKOMUNIKACE a.s., www.2n.cz 48/116...
  • Page 49 2N TELEKOMUNIKACE a.s., www.2n.cz 49/116...
  • Page 50 2N TELEKOMUNIKACE a.s., www.2n.cz 50/116...
  • Page 51 2N TELEKOMUNIKACE a.s., www.2n.cz 51/116...
  • Page 52 2N TELEKOMUNIKACE a.s., www.2n.cz 52/116...
  • Page 53 Wall (surface) mounting 2N TELEKOMUNIKACE a.s., www.2n.cz 53/116...
  • Page 54 2N TELEKOMUNIKACE a.s., www.2n.cz 54/116...
  • Page 55 2N TELEKOMUNIKACE a.s., www.2n.cz 55/116...
  • Page 56 2N TELEKOMUNIKACE a.s., www.2n.cz 56/116...
  • Page 57 2N TELEKOMUNIKACE a.s., www.2n.cz 57/116...
  • Page 58: Two Module Box

    2.2.2 Two Module Box Flush mounting – classic bricks 2N TELEKOMUNIKACE a.s., www.2n.cz 58/116...
  • Page 59 2N TELEKOMUNIKACE a.s., www.2n.cz 59/116...
  • Page 60 2N TELEKOMUNIKACE a.s., www.2n.cz 60/116...
  • Page 61 2N TELEKOMUNIKACE a.s., www.2n.cz 61/116...
  • Page 62 Flush mounting – plasterboard 2N TELEKOMUNIKACE a.s., www.2n.cz 62/116...
  • Page 63 2N TELEKOMUNIKACE a.s., www.2n.cz 63/116...
  • Page 64 2N TELEKOMUNIKACE a.s., www.2n.cz 64/116...
  • Page 65 Module flush mounting 2N TELEKOMUNIKACE a.s., www.2n.cz 65/116...
  • Page 66 2N TELEKOMUNIKACE a.s., www.2n.cz 66/116...
  • Page 67 2N TELEKOMUNIKACE a.s., www.2n.cz 67/116...
  • Page 68 2N TELEKOMUNIKACE a.s., www.2n.cz 68/116...
  • Page 69 2N TELEKOMUNIKACE a.s., www.2n.cz 69/116...
  • Page 70 Wall (surface) mounting 2N TELEKOMUNIKACE a.s., www.2n.cz 70/116...
  • Page 71 2N TELEKOMUNIKACE a.s., www.2n.cz 71/116...
  • Page 72 2N TELEKOMUNIKACE a.s., www.2n.cz 72/116...
  • Page 73 2N TELEKOMUNIKACE a.s., www.2n.cz 73/116...
  • Page 74 2N TELEKOMUNIKACE a.s., www.2n.cz 74/116...
  • Page 75: Module Dimensions

    9155011 – Flush mounting frame, 1 module 9155012 – Flush mounting frame, 2 modules 9155021 – Surface mounting frame, 1 module 9155022 – Surface mounting frame, 2 modules Backplates 9155061 – 1 module 9155062 – 2 modules 2N TELEKOMUNIKACE a.s., www.2n.cz 75/116...
  • Page 76: Electric Installation

    2N Access Unit Power Supply Connection 2N Access Unit can be powered either from an external 12 V / 1 A DC source or directly from the LAN equipped with PoE 802.3af supporting network elements. External power supply For reliability reasons, use a 12 V ±15 % SELV supply dimensioned to the current...
  • Page 77 12 W for feeding of itself and the connected modules. Combined power supply 2N Access Unit can be fed from an external power supply and PoE at the same time. In this configuration, the maximum power for the connected modules is available.
  • Page 78 PoE phantom supply (typically TP-LINK) to spare-pair supply – Phihong injector, Part No. 91378100 change the Ethernet bitrate to Half Duplex – 10 mbps UTP Cable Connection to Access Unit Terminal Board Legend to the figure PoE, LAN (PoE according to 802.1af) terminals...
  • Page 79 External supply terminals for 2NAccess Unit – 12 V / 1 A RESET RESET / FACTORY RESET button RJ-45 RJ-45 adapter connector – no need to use the PoE, RD and TD terminals for this connector 2N TELEKOMUNIKACE a.s., www.2n.cz 79/116...
  • Page 80 The electric lock is opened by power supply connection. The magnetic lock is opened by power supply disconnection. Wiring diagram of IN1, IN2 and IN3 terminals in active mode Wiring diagram of IN1, IN2 and IN3 terminals in passive mode 2N TELEKOMUNIKACE a.s., www.2n.cz 80/116...
  • Page 81 The button is located in the middle of the lower part in version 586v4 Press the button shortly (< 1 s) to restart the system without changing configuration. 2N Access Unit Connectors, PCB Version 599v3 2N TELEKOMUNIKACE a.s., www.2n.cz 81/116...
  • Page 82 2N Access Unit Connectors, PCB Version 586v2 2N TELEKOMUNIKACE a.s., www.2n.cz 82/116...
  • Page 83 2N Access Unit Connectors, PCB Version 586v4 get the current IP address, follow the instructions below: Press and hold the RESET button. Wait for approx. 20 s until the red and green LEDs in the right-hand bottom part of the motherboard shine simultaneously (LED8 and LED9 in the figure above).
  • Page 84 (approx. 20 s). Wait until the red LED goes off (approx. 5 s). Wait until the green LED goes off and the red LED comes on again (another 5 s). Release the RESET button. 2N TELEKOMUNIKACE a.s., www.2n.cz 84/116...
  • Page 85 Helps to secure the system against tampering. The information about switch unauthorised manipulation with the device can be used in the menu Hardware / Digital Inputs / Tamper Switch, in Automation a it is also logged in the Events. 2N TELEKOMUNIKACE a.s., www.2n.cz 85/116...
  • Page 86 For this way of protection we recommend a 1 A / 1000 V diode (e.g., 1N4007, 1N5407, 1N5408) connected antiparallel to the device. 2N TELEKOMUNIKACE a.s., www.2n.cz 86/116...
  • Page 87: Extending Module Connection

    2.4 Extending Module Connection 2N Access Unit allows to connect following extending modules: Keypad Touch keypad 125 kHz RFID card reader 13.56 MHz RFID card reader 13.56 MHz RFID Card Reader NFC support Bluetooth & RFID reader 125kHz, 13.56MHz, NFC Bluetooth &...
  • Page 88 Module Power Supply All the modules connected to 2N Access Unit , except for the Tamper Switch, are powered from the bus. The available bus power output depends on the power supply type. The basic unit can use a 2 A power supply to increase the bus power available to the modules connected.
  • Page 89 ) is used for a numeric access to the system. The module contains two bus connectors for 2N Access Unit These two connectors are fully interchangeable and can be used either as inputs from the basic unit or outputs to other modules.
  • Page 90 Part No. 9155047 ) provides a numerical input in the system. The module contains two 2N Access Unit bus connectors. These two connectors are fully interchangeable and can be used both as inputs from the main unit and outputs to other modules.
  • Page 91 Mobile Key tablet/card access control, making user calls and/or other functions. ® NFC – a licensed function, for 2N Mobile Key for Android only. The module contains two bus connectors. These two connectors are fully interchangeable and can be used either as inputs from the basic unit or outputs to other modules.
  • Page 92 Mobile Key tablet/card access control, making user calls and/or other functions. ® NFC – a licensed function, for 2N Mobile Key for Android only. The module contains two bus connectors. These two connectors are fully interchangeable and can be used either as inputs from the basic unit or outputs to other modules.
  • Page 93 ) is used for code/card access control, making user calls and/or other functions. The keypad surface is very sensitive yet weatherproof at the same time. ® NFC – a licensed function, for 2N Mobile Key for Android only. The module contains two bus connectors.
  • Page 94 ® NFC – a licensed function, for 2N Mobile Key for Android only. The module contains two bus connectors. These two connectors are fully interchangeable and can be used either as inputs from the basic unit or outputs to other modules.
  • Page 95 The module contains two 2N Access Unit bus connectors. These two connectors are fully interchangeable and can be used both as inputs from the main unit and outputs to other modules.
  • Page 96 Tamper switch input, Part No. 9155038 Infopanel Module The Infopanel module ( Part No. 9155030 ) is used for inserting and backlighting of printed information. The module contains two bus connectors for 2N Access Unit 2N TELEKOMUNIKACE a.s., www.2n.cz 96/116...
  • Page 97 The Wiegand module ( Part No. 9155037 ) helps connect an external Wiegand device (RFID card reader, fingerprint or other biometric data reader) and/or connect 2N Access Unit to an external security exchange. All the inputs and outputs are galvanically isolated from 2N Access Unit with the insulation strength of 500 V DC.
  • Page 98 Isolated input for open LED IN, input activated by GND LEDIN Isolated input for open LED IN, input activated by +U   active supply LED indicator +U WIEGAND OUT   TAMPER Tamper switch input, Part No. 9155038 2N TELEKOMUNIKACE a.s., www.2n.cz 98/116...
  • Page 99 Security relay Part No. 9159010 ) is used for enhancing security between the access unit and the connected electric lock. It significantly enhances security of the connected electric lock as it prevents unlocking by forced opening of the 2N Access Module Function: ®...
  • Page 100 To the passive output in series with the external power supply. er supply. The device also supports a Departure button connected between the ‘PB’ and ‘- HeliosIP/2N IP intercom’ terminals. Press the Departure button to activate the output for 5 seconds. Status signalling...
  • Page 101 2.18 higher, necessary reprogram ® IP Security Relay using the instructions above. FAQ: 2N® IP Security Relay device description and use with 2N IP intercom Video Tutorial Door intercoms 2N IP – Security Relay 2N TELEKOMUNIKACE a.s., www.2n.cz 101/116...
  • Page 102 Connection: 2N TELEKOMUNIKACE a.s., www.2n.cz 102/116...
  • Page 103: Mounting Completion

    Hang the wall mounting frame on the hook in the upper part and then screw it tight in the bottom part. Caution Improper mounting may deteriorate the 2N Access Unit waterproofness. Water infiltration may damage the electronic part. Make sure that all the holes are filled with some waterproof material –...
  • Page 104 Make sure that the bases are levelled properly to avoid water leakage and electronic damage. The examples in the figures below show incorrectly assembled bases. This happens, in particular, where the screws are tightened first. 2N TELEKOMUNIKACE a.s., www.2n.cz 104/116...
  • Page 105 2N TELEKOMUNIKACE a.s., www.2n.cz 105/116...
  • Page 106: Maintenance

    Do not use aggressive detergents (such as abrasives or strong disinfectants). Clean the device in dry weather in order to make waste water evaporate quickly. Warning Prevent water from getting inside the access unit. Do not use Alcohol-based cleaners. 2N TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 107: Technical Parameters

    2 V), up to 400 mA Tamper switch is part of the 2N Access Unit Inputs: passive / active mode (-30 V to +30 V DC) OFF = open or U > 1.5 V ON = short-circuit or U < 1.5 V RFID card reader Frequency: 13.56 MHz &...
  • Page 108 ® ® Compatible with 2N IP Verso, 2N LTE Verso and 2N Access Unit Mobile app. support: Android 5.0 and higher, iOS 11.0 and higher Mechanical properties Cover: robust zinc casting with surface finish (minor surface shade nuances are acceptable) 91550XX –...
  • Page 109 Weight: Max net weight: 2 kg / max gross weight: 0.5 kg – based on configuration Cover rating: IP54 2N TELEKOMUNIKACE a.s., www.2n.cz 109/116...
  • Page 110: Supplementary Information

    5. Supplementary Information Here is what you can find in this section: 5.1 Troubleshooting 5.2 Directives, Laws and Regulations 5.3 General Instructions and Cautions 2N TELEKOMUNIKACE a.s., www.2n.cz 110/116...
  • Page 111: Troubleshooting

    5.1 Troubleshooting For the most frequently asked questions refer to faq.2n.cz 2N TELEKOMUNIKACE a.s., www.2n.cz 111/116...
  • Page 112: Directives, Laws And Regulations

    5.2 Directives, Laws and Regulations 2N Access Unit conforms to the following directives and regulations: 2014/35/EU on the harmonisation of the laws of the Member States relating to the making available on the market of electrical equipment designed for use within certain...
  • Page 113 2N TELEKOMUNIKACE a. s. is not liable neither for any limitation of such a product’s functionality, nor for any damage, loss or injury relating to such a potential limitation of functionality.
  • Page 114: General Instructions And Cautions

    The consumer shall, at its own expense, obtain software protection of the product. The manufacturer shall not be held liable and responsible for any damage incurred as a result of the use of deficient or substandard security software. 2N TELEKOMUNIKACE a.s., www.2n.cz 114/116...
  • Page 115 Make sure that the devices to be disposed of are complete. Do not throw battery packs into fire. Battery packs may not be taken into parts or short-circuited either. 2N TELEKOMUNIKACE a.s., www.2n.cz 115/116...
  • Page 116 2N TELEKOMUNIKACE a.s. Modřanská 621, 143 01 Prague 4, Czech Republic Phone: +420 261 301 500, Fax: +420 261 301 599 E-mail: sales@2n.cz Web: www.2n.cz v2.13 2N TELEKOMUNIKACE a.s., www.2n.cz 116/116...

Table of Contents