Summary of Contents for 2N Access Unit

  • Page 1 ® 2N Access Unit Access Control Configuration Manual Version: 2.16 www.2n.cz...
  • Page 2 2N TELEKOMUNIKACE a.s. administers the FAQ database to help you quickly find information and to answer your questions about 2N products and services. On www. faq.2n.cz you can find information regarding products adjustment and instructions for optimum use and procedures „What to do if...".
  • Page 3 3. Function Licensing 4. Signalling of Operational Statuses 5. Intercom Configuration 5.1 Status 5.2 Directory 5.3 Hardware 5.4 Services 5.5 System 6. Supplementary Information 6.1 Troubleshooting 6.2 Directives, Laws and Regulations 6.3 General Instructions and Cautions 2N TELEKOMUNIKACE a.s., www.2n.cz 3/84...
  • Page 4: Product Overview

    The following symbols and pictograms are used in the manual: Safety Always abide by this information to prevent persons from injury. Warning Always abide by this information to prevent damage to the device. Caution Important information for system functionality. 2N TELEKOMUNIKACE a.s., www.2n.cz 4/84...
  • Page 5 Useful information for quick and efficient functionality. Note Routines or advice for efficient use of the device. 2N TELEKOMUNIKACE a.s., www.2n.cz 5/84...
  • Page 6: Express Wizard For Basic Settings

    2. Express Wizard for Basic Settings LAN Connection Setting You have to know the IP address to connect to the 2N® Access Unit configuration interface successfully. Automatic IP address retrieval from the DHCP server is set by ® default in the Access Unit .
  • Page 7 FAQ: IP address - How to get the 2N® Access Unit IP address? 2N TELEKOMUNIKACE a.s., www.2n.cz 7/84...
  • Page 8: Firmware Update

    Firmware Update ® We also recommend you to update your firmware upon the first login to the 2N Access Unit . Refer to www.2n.cz for the latest firmware version. Press the Update Firmware button in the System Maintenance menu to upload firmware. The device will get restarted upon upload and only then the updating process will be complete.
  • Page 9: Electric Lock Switching Settings

    Enable the switch in the Switch Enabled parameter on the Hardware / Switches / Switch 1 tab, set the Controlled Output to the intercom output to which the electric door lock is connected. Now set one or more activation codes for the electric door lock switching. 2N TELEKOMUNIKACE a.s., www.2n.cz 9/84...
  • Page 10: Function Licensing

    3. Function Licensing ® Access Unit provides just one licensed function - NFC. 2N TELEKOMUNIKACE a.s., www.2n.cz 10/84...
  • Page 11: Signalling Of Operational Statuses

    Refer to the Users subsection for the deactivation code settings. Profile activated This tone signals profile activation. This function helps enable alerting of a user group in an office, for example. Refer to the Profile subsection for the activation code settings. 2N TELEKOMUNIKACE a.s., www.2n.cz 11/84...
  • Page 12 A successful launch is signalled by this tone combination. Connected to LAN, IP address received 2N® Access Unit logs in upon the internal application launch. A successful LAN login is signalled by this tone combination. Disconnected from LAN, IP address lost ®...
  • Page 13: Intercom Configuration

    5. Intercom Configuration Start Screen ® The start screen is an introductory overview screen displayed upon login to the 2N Access Unit web interface. Use the button in the left-hand upper corner of the following web interface pages to return to this screen anytime.
  • Page 14 The start screen is also the first menu level and quick navigation (click on a tile) to selected intercom configuration sections. Some tiles also display the state of selected services. Video Tutorial: New web interface of 2N® Helios IP intercoms 2N TELEKOMUNIKACE a.s., www.2n.cz 14/84...
  • Page 15: Configuration Menu

    Hardware, Services System including submenus; refer to the survey below. Status ® Device – essentials on the 2N Access Unit Services – information on active services and their states ® Licence – current states of licences and available Access Unit functions Access Log –...
  • Page 16 Licence – licence settings, trial licence activation Certificates – certificate and private key settings Auto Provisioning – automatic firmware and configuration update settings Syslog – syslog message sending settings Maintenance – backup and configuration reset, firmware update 2N TELEKOMUNIKACE a.s., www.2n.cz 16/84...
  • Page 17 Access Unit . The menu is divided into the following tabs: Device This tab displays basic information on the intercom model, its features, firmware and bootloader versions and so on. 2N TELEKOMUNIKACE a.s., www.2n.cz 17/84...
  • Page 18 Services This tab displays the statuses of the network interface and selected services. 2N TELEKOMUNIKACE a.s., www.2n.cz 18/84...
  • Page 19 Licence ® This tab displays the list of licensed functions of the Access Unit including their current availability (on the basis of a valid licence key entered in the System / Licences menu). 2N TELEKOMUNIKACE a.s., www.2n.cz 19/84...
  • Page 20: Access Log

    Access Log Access Log tab displays the last 10 records on the cards applied. Each record includes the card tapping time, card ID and type and description details (validity, card owner, etc.). 2N TELEKOMUNIKACE a.s., www.2n.cz 20/84...
  • Page 21 Events This tab displays activity of the device (switches, signalling leds, pressed keys on keypad etc.). It also allows filtering between events through the 13 optional parameters. 2N TELEKOMUNIKACE a.s., www.2n.cz 21/84...
  • Page 22 Or, you can enter the position number and push to move to the position quickly. If you know the user’s name, push to find its position. 2N TELEKOMUNIKACE a.s., www.2n.cz 22/84...
  • Page 23: List Of Parameters

    Code – set a private user switch activation code: up to 16 characters including digits 0–9 only. Time Profile – assign a time profile to the switch code to define the code validity. If the time profile is inactive, the switch will not be activated by the code. 2N TELEKOMUNIKACE a.s., www.2n.cz 23/84...
  • Page 24 USB card reader. The card number will be automatically entered into the Card ID field. Make sure that a PC driver is installed to make the USB card reader work properly. Refer to www.2n.cz 2N TELEKOMUNIKACE a.s., www.2n.cz 24/84...
  • Page 25 It is possible to read the card ID via an RFID card reader. Proceed as follows: ® Go to the Helios IP USB Driver settings. Set up the COM port for the connected reader. ® Press Read button Helios interface. 2N TELEKOMUNIKACE a.s., www.2n.cz 25/84...
  • Page 26 Tap the card on the card reader. The card ID is successfully read. Do not forget to save the configuration. 2N TELEKOMUNIKACE a.s., www.2n.cz 26/84...
  • Page 27: Time Profiles

    Access Unit to activate/deactivate a function after arriving in/before leaving your office, for example. Refer to the Directory / Time Profiles menu for the time profile settings. List of Parameters 2N TELEKOMUNIKACE a.s., www.2n.cz 27/84...
  • Page 28 ), the last table row (Holiday) is applied regardless of the day in a week. Make sure that the real time settings are correct (refer to the Date and Time subsection) to make this function work properly. 2N TELEKOMUNIKACE a.s., www.2n.cz 28/84...
  • Page 29 Click a date once to select a fixed holiday, click twice to select a variable holiday and click for the third time to remove the holiday from the holiday list. 2N TELEKOMUNIKACE a.s., www.2n.cz 29/84...
  • Page 30: Access Cards

    ID is shortened to 6 or 8 characters for transmission (depending on the transmission parameters). If you apply a card to an internal reader, you will receive a complete ID, which is typically longer (8 chars or more). The last 6 or 8 characters, 2N TELEKOMUNIKACE a.s., www.2n.cz 30/84...
  • Page 31 ® however, are identical. This is useful for comparing card IDs with the 2N Access Unit database: if the IDs to be compared have different lengths, they are compared from the end and match has to be found in 6 characters at least. If they have identical lengths, all the characters are compared.
  • Page 32 Description – enter such information as the card owner name and similar. The description gets displayed in the Records menu whenever the card is applied ® and helps you find the card list items more easily without affecting the 2N Access Unit function.
  • Page 33 5.3.5 Extenders 5.3.1 Switches Switches provide a very flexible and efficient control of such peripherals connected to the Access Unit as electric door locks, lighting, additional ringing signalling, and so on. ® Access Unit allows you to configure to 2 independent all-purpose switches.
  • Page 34 Distinguish on/off codes – set a switch code mode in which odd codes (1, 3, etc.) are used for switch activation and even codes (2, 4, etc.) are for switch deactivation. This mode can only be used if the switch is set to the bistable mode. 2N TELEKOMUNIKACE a.s., www.2n.cz 34/84...
  • Page 35 Codes 00 and 11 cannot be entered from the numeric keypad. Confirm the code with *. The code length is up to 16 characters. Time Profile – assign a time profile to the switch code to control its validity. 2N TELEKOMUNIKACE a.s., www.2n.cz 35/84...
  • Page 36 Switch-Off Command – set the command to be sent to the external device (WEB relay, e.g.) upon switch deactivation. The command is sent via the HTTP (GET request) and must be as follows: http://ip_address/path . E.g.: http://192. 168.1.50/relay1=off 2N TELEKOMUNIKACE a.s., www.2n.cz 36/84...
  • Page 37: Card Reader

    The volume values are relative against the set master volume. Switch activation tone volume – set the volume of the switch activation tone. The volume values are relative against the set master volume. 5.3.3 Card Reader 2N TELEKOMUNIKACE a.s., www.2n.cz 37/84...
  • Page 38 - one beep signals both valid and invalid cards, None - acoustic signalling is disabled. Direction - set direction to be writen in system: Not Specified/In/Out RFID Interface - Allows to choose the permitted types of cards (select/unselect). 2N TELEKOMUNIKACE a.s., www.2n.cz 38/84...
  • Page 39: Digital Inputs

    List of Parameters Assigned input – define one (or none) of the logical inputs for secured state ® detection. The secured state is then signalled by a red LED on the 2N Access Unit Input mode – set the active level of the input (polarity).
  • Page 40 The models equipped with one digital input at least help connect an open door sensor and signal any unauthorised door opening or door closing failure with a timeout. The ® events are written into a log and read out using HTTP API (refer to the 2N Helios IP HTTP API manual).
  • Page 41 DoorOpenTooLong state is detected. Note Menu Digital Inputs is available for models: ® Helios IP Verso ® ® Helios IP Vario Helios IP Force if an internal card reader is installed ® Access Unit 2N TELEKOMUNIKACE a.s., www.2n.cz 41/84...
  • Page 42 The modules can also be configured via the text row with a list of parameters (parameter_name=parameter_value) separated with semicolons. At present, just a few of these parameters are available. The other parameters are not public as they are rather experimental and can be modified in the future. 2N TELEKOMUNIKACE a.s., www.2n.cz 42/84...
  • Page 43: Backlight Brightness

    LED on/off contrast and potential LED state identification problems. Button Module Configuration Button functions – assign user positions to the buttons. 2N TELEKOMUNIKACE a.s., www.2n.cz 43/84...
  • Page 44: Keypad Module Configuration

    Button functions – assign user positions to the buttons. Keypad Module Configuration No parameters are available to the public at present. Infopanel Module Configuration No parameters are available to the public at present. 2N TELEKOMUNIKACE a.s., www.2n.cz 44/84...
  • Page 45: Card Reader Module Configuration

    - one beep signals both valid and invalid cards, None - acoustic signalling is disabled. Forward to Wiegand output - set a group of Wiegand outputs to which all the received RFID card IDs will be resent. 2N TELEKOMUNIKACE a.s., www.2n.cz 45/84...
  • Page 46: I/O Module Configuration

    I/O Module Configuration Module name – set the module name for input/output specification in the SetOutput, GetInput and InputChanged objects in the 2N® Helios IP Automation settings. Wiegand Module Configuration The Wiegand module is equipped with the input and output Wiegand interfaces, which are mutually independent, have separate settings and can receive and send codes at the same time.
  • Page 47 - one beep signals both valid and invalid cards, None - acoustic signalling is disabled. Forward to Wiegand output – set the group of Wiegand outputs to which all the received codes shall be resent. 2N TELEKOMUNIKACE a.s., www.2n.cz 47/84...
  • Page 48 Transmitted code format - set the format for the codes to be transmitted (Wiegand 26, 32, 37 and RAW). Output Wiegand group - assign the output Wiegand to a group to which the codes from the connected card readers or Wiegand inputs can be resent. 2N TELEKOMUNIKACE a.s., www.2n.cz 48/84...
  • Page 49 You can also send e-mails via Automation using the Action.SendEmail action. Note The E-mail function is available with the Gold or Enhanced Integration licence only. 2N TELEKOMUNIKACE a.s., www.2n.cz 49/84...
  • Page 50 SMTP server communication encryption. Choose one of the three sets of user certificates and private keys (refer to the Certificates subs.) or keep the Self Signed setting, in which the certificate automatically generated upon the first intercom power up is used. 2N TELEKOMUNIKACE a.s., www.2n.cz 50/84...
  • Page 51 Test e-mail address field and press the button. The current e-mail sending state is continuously displayed in the window for you to detect an e-mail setting problem if any on the intercom or another network element. 2N TELEKOMUNIKACE a.s., www.2n.cz 51/84...
  • Page 52: E-Mail On Card

    The following options are available: Denied events – e-mail shall be sent when an invalid RFID card is applied. All events – e-mail shall be sent when any card is applied. Never – e-maily shall not be sent. 2N TELEKOMUNIKACE a.s., www.2n.cz 52/84...
  • Page 53 ID, which will be replaced with the actual value before sending. Refer to the table of substitute symbols below: $User$ Called username $DateTime$ Current date and time $AuthId$ User authentication ID $HeliosId$ Intercom identification 2N TELEKOMUNIKACE a.s., www.2n.cz 53/84...
  • Page 54 . Typically, Helios IP Automation is used in applications that require complex interconnections with third party systems. ® ® Refer to the Helios IP Automation Configuration Manual for the Helios IP Automation function and configuration details. 2N TELEKOMUNIKACE a.s., www.2n.cz 54/84...
  • Page 55 5.4.3 HTTP API ® Helios IP HTTP API is an application interface designed for control of selected 2N Helios IP functions via the HTTP . It enables 2N Helios IP intercoms to be integrated easily with third party products, such as home automation, security and monitoring systems, etc.
  • Page 56: Web Server

    5.4.4 Web Server 2N TELEKOMUNIKACE a.s., www.2n.cz 56/84...
  • Page 57 List of Parameters Device Name– set the device name to be displayed in the right upper corner of the web interface, login window and other applications if available (2N® Helios IP Manager, 2N® Helios IP Network Scanner, etc). Web Interface Language – set the default language for administration web server login.
  • Page 58 The port setting will not be applied until the Access Unit gets restarted. ® User Certificate – specify the user certificate and private key for the 2N Access Unit HTTP server – user web browser communication encryption. Choose one of...
  • Page 59 Community String - text string representing the access key to the MIB table objects. Trap IP Address - IP address to which the SNMP traps are to be sent. Download MIB File - download the current MIB definition from a device. 2N TELEKOMUNIKACE a.s., www.2n.cz 59/84...
  • Page 60 - enter the device location (1st floor, e.g.). IP Address - enter up to 4 valid IP addresses for SNMP agent access to block access from other addresses. If the field is empty, the device may be accessed from any IP address. 2N TELEKOMUNIKACE a.s., www.2n.cz 60/84...
  • Page 61 As the Access Unit is connected to the LAN, make sure that its IP address has been set correctly or obtained from the LAN DHCP server. Configure the IP address and DHCP in the Network subsection. 2N TELEKOMUNIKACE a.s., www.2n.cz 61/84...
  • Page 62 EAP-MD5 or EAP-TLS authentication. Set this function on the 802.1x tab. ® The Trace tab helps you launch capture of incoming and outgoing packets on the 2N Access Unit network interface. The file with captured packets can be downloaded for Wireshark processing, e.g.
  • Page 63 Trusted Certificate – specify the set of trusted certificates for verification of the RADIUS server public certificate validity. Choose one of three sets of certificates; refer to the Certificates subsection. If no trusted certificate is included, the RADIUS public certificate is not verified. 2N TELEKOMUNIKACE a.s., www.2n.cz 63/84...
  • Page 64: Date And Time

    5.5.2 Date and Time If you control validity of lock activation codes and similar by time profiles, make sure ® that the Access Unit internal date and time are set correctly. 2N TELEKOMUNIKACE a.s., www.2n.cz 64/84...
  • Page 65 Synchronise – push the button to synchronise the Access Unit time value with your PC time value. Time Zone – set the time zone for the installation site to define time shifts and winter/summer time transitions. 2N TELEKOMUNIKACE a.s., www.2n.cz 65/84...
  • Page 66 Access Unit time synchronisation. 5.5.3 Licence ® Some Access Unit functions are available with a valid licence key only. Refer to ® Function Licensing subsection for the list of Access Unit licensing options. 2N TELEKOMUNIKACE a.s., www.2n.cz 66/84...
  • Page 67 Integration licence are available. NFC Support – check whether the functions activated. Trial Licence State – check the trial licence state (Non-Activated, Activated, Expired). Licence Expiry – display the remaining time of the trial licence validity. 2N TELEKOMUNIKACE a.s., www.2n.cz 67/84...
  • Page 68 Access Unit intercoms allow you to load up to three sets of trusted ® certificates, which help authenticate LAN devices for communication with the 2N Access Unit , plus three sets of user certificates and private keys for communication encryption.
  • Page 69 If you use the Self Signed certificate for encryption of the intercom web server – browser communication, the communication is secure, but the ® browser will warn you that it is unable to verify the 2N Access Unit certificate validity.
  • Page 70: Auto Provisioning

    ® gets restarted (approx. 30 s). Hence, we recommend you to update when the 2N Access Unit traffic is very low (at night, e.g.).
  • Page 71 The Access Unit periodically downloads a file from the server and gets reconfigured without getting restarted. List of Parameters Firmware/Configuration Update Enabled – enable automatic firmware /configuration updating from the TFTP/HTTP server. 2N TELEKOMUNIKACE a.s., www.2n.cz 71/84...
  • Page 72 User Authentication – Allows to use credentials for connect with server ® At Boot Time – enable check and/or execution of update upon every 2N Access Unit start. Update Period – set the update period: Hourly, Daily, Weekly or Monthly.
  • Page 73 The file to be downloaded is corrupted or of a wrong type. My2N / TR069 Use this tab to enable and configure remote intercom management via the TR-069 protocol. TR-069 helps you reliably configure intercom parameters, update and back up configuration and/or upgrade device firmware. 2N TELEKOMUNIKACE a.s., www.2n.cz 73/84...
  • Page 74 Next synchronisation in – display the time period in which the intercom shall contact a remote ACS. Connection status – display the current ACS connection state or error state description if necessary. My2N ID – unique identifier of the company created via the My2N portal. 2N TELEKOMUNIKACE a.s., www.2n.cz 74/84...
  • Page 75 Access Unit allow you to send system messages to the Syslog server including relevant information on the device states and processes for recording, ® analysis and audit. It is unnecessary to configure this service for common 2N Access Unit operation.
  • Page 76: Maintenance

    ® Backup Configuration – back up the complete current configuration of your 2N Access Unit . Press the button to download the configuration file to your PC.
  • Page 77 ® Restart Device – restart the Access Unit . The process takes about 30 s. ® When the Access Unit has obtained the IP address upon restart, the login window will get displayed automatically. 2N TELEKOMUNIKACE a.s., www.2n.cz 77/84...
  • Page 78: Supplementary Information

    6. Supplementary Information Here is what you can find in this section: 6.1 Troubleshooting 6.2 Directives, Laws and Regulations 6.3 General Instructions and Cautions 2N TELEKOMUNIKACE a.s., www.2n.cz 78/84...
  • Page 79: Troubleshooting

    6.1 Troubleshooting For the most frequently asked questions refer to faq.2n.cz 2N TELEKOMUNIKACE a.s., www.2n.cz 79/84...
  • Page 80: Directives, Laws And Regulations

    NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. 2N TELEKOMUNIKACE a.s., www.2n.cz 80/84...
  • Page 81 Consult the dealer or an experienced radio/TV technician for help. Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. 2N TELEKOMUNIKACE a.s., www.2n.cz 81/84...
  • Page 82: General Instructions And Cautions

    The consumer shall, at its own expense, obtain software protection of the product. The manufacturer shall not be held liable and responsible for any damage incurred as a result of the use of deficient or substandard security software. 2N TELEKOMUNIKACE a.s., www.2n.cz 82/84...
  • Page 83: Electric Waste And Used Battery Pack Handling

    Make sure that the devices to be disposed of are complete. Do not throw battery packs into fire. Battery packs may not be taken into parts or short-circuited either. 2N TELEKOMUNIKACE a.s., www.2n.cz 83/84...
  • Page 84 2N TELEKOMUNIKACE a.s. Modřanská 621, 143 01 Prague 4, Czech Republic Phone: +420 261 301 500, Fax: +420 261 301 599 E-mail: sales@2n.cz Web: www.2n.cz v2.16 2N TELEKOMUNIKACE a.s., www.2n.cz 84/84...