Infopanel Module; Wiegand Module - 2N Access Unit Installation Manual

Hide thumbs Also See for Access Unit:
Table of Contents

Advertisement

IN2
IN2 terminals for input in passive/active mode (−30 V to +30 V DC)
OFF = open or U > 1.5 V
ON = short-circuit or U < 1.5 V
TAMPER
Tamper switch input, Part No. 9155038

Infopanel Module

The Infopanel module (
printed information.
The module contains two bus connectors for
These two connectors are fully interchangeable and can be used either as inputs
from the basic unit or outputs to other modules.
If this module is the last one on the bus, one of the connectors remains
unconnected.
The module package includes a 220 mm long interconnecting cable.
Name tag dimensions: 69.2 (W) x 86.7 (H) mm (dimensional tolerance: +0; -0.5
mm).
For the printing template refer to www.2n.cz

Wiegand Module

The Wiegand module (
(RFID card reader, fingerprint or other biometric data reader) and/or connect 2N
Access Unit
to an external security exchange. All the inputs and outputs are
galvanically isolated from
The module contains two bus connectors for
These two connectors are fully interchangeable and can be used either as inputs
from the basic unit or outputs to other modules.
If this module is the last one on the bus, one of the connectors remains
unconnected.
The module package includes an 80 mm long interconnecting cable.
Configure the module name in the Module name parameter in the Hardware /
Extenders menu.
The LED IN input is addressed as follows:
module2.input1.
The Tamper input is addressed as follows:
2N TELEKOMUNIKACE a.s., www.2n.cz
IN
IN
Part No. 9155030
) is used for inserting and backlighting of
Part No. 9155037
) helps connect an external Wiegand device
®
2N
Access Unit
®
2N
Access Unit
with the insulation strength of 500 V DC.
®
2N
Access Unit
<module_name>.<input1>
<module_name>.<tamper>
.
®
.
, e.g.
, e.g.
81/98