Error code
Cause
Lack of ionisation
detection during
Lack of ionisation
08A
detection during
Solution
If no flame is visible during ignition, but a spark
appears at the ignition rod (the V symbol on the
burner in the fire):
ignition
The gas pressure in your home is insufficient or the
gas valve is defective. In either case, contact your
installer.
If no flame is visible during ignition, and no
spark appears at the ignition rod (the V symbol
on the burner in the fire):
ignition
Check the fire to ensure that there is
no contact between the ignition rod
(the V symbol in the burner) and the
other elements.
Check that the cable is correctly
plugged into the technical unit (see
'ionisation' in section 20: Wiring
diagram).