Troubleshooting - Kalfire GP75/59F User Manual

Closed gas fire with prestige burner
Hide thumbs Also See for GP75/59F:
Table of Contents

Advertisement

8

Troubleshooting

There are five types of malfunctions that may arise:
1.
'Permanent' malfunction (indicated by 'F'): this type of malfunction is not resolved
automatically; the fire will remain inactivated for 24 hours.
2.
Malfunctions that trigger automatic self-recovery (indicated by 'ALARM' or 'A'): this
type of malfunction is automatically resolved, provided that the cause of the failure has
been identified.
3.
Communication malfunction (indicated by 'E'): this type of malfunction is linked to
communication problems between any of the printed circuit boards and the remote
control. They are resolved automatically by re-establishing the remote control's link
with the fire's technical unit. Press
4.
Signal malfunction (indicated by 'NOLK 0 of 1' or a flashing RF icon
malfunction arises when the remote control cannot communicate with the fire. It is not
resolved automatically.
5.
Fire shutdown: the burner control must be cut off every 16 hours (in compliance with
the verification requirements in force). During this shutdown, all of the burner control
once.