Kalfire GP75/59F User Manual page 27

Closed gas fire with prestige burner
Hide thumbs Also See for GP75/59F:
Table of Contents

Advertisement

operations are tested. Following this, the fire is automatically set to 'Off' and remains in
this state until it is manually set to 'On'.
8.1
Troubleshooting solutions or restarting after a malfunction
The burner control's automatic settings depend on which type of gas is used: natural gas or
propane/butane. In the case of natural gas, the burner will make 3 automatic ignition
attempts, while in the case of propane/butane, it makes only 1 attempt. If ignition fails, the
error code A08 appears immediately and 'ER' (Error) displays at the top left of the screen.
Using the remote control, 2 more ignition attempts can be tried (or 1 attempt in the case of
propane/butane). If this new attempt also fails, the burner is automatically locked (error code
08F).
27

Hide quick links:

Advertisement

Table of Contents
loading