Displaying Flow Rate Data - YOKOGAWA DY025 User Manual

Digitalyewflo vortex flowmeter dy series vortex flow converter dya series
Hide thumbs Also See for DY025:
Table of Contents

Advertisement

4.5.2 Displaying Flow Rate Data

Flowrate data can be displayed on the BT200 screen
according to the following procedure.
———WELCOME———
BRAIN TERMINAL
ID:BT200
Check connection
Push ENTER key
UTIL FEED
PARAM
01:MODEL
digitalYEWFLO
02:TAG NO.
03:SELF CHECK
GOOD
OK
MENU
A:DISPLAY
B:EASY SETUP
C:BASIC SETUP
D:AUX. SETUP
E:METER SETUP
H:ADJUST
HOME SET
ADJ
ESC
PARAM
A10:FLOW RATE(%)
80.0%
A20:FLOW RATE
100m3/h
A30:TOTAL
1417
DATA DIAG PRNT
ESC
PARAM
A10:FLOW RATE(%)
80.0%
A20:FLOW RATE
100m3/h
A30:TOTAL
1417
DATA DIAG PRNT
ESC
Function Key
Turn the power on and the
screen on the left
"Please wait...." is
displayed for a few
minutes.
Pressing the "ENTER" key
causes the initial data
screen on the left to be
displayed.
The tag number
specified upon
ordering is entered.
or
Inverse Video Bar
Pressing the "F4" or
"ENTER" causes the menu
screen on the left to be
displayed.
With "A : DISPLAY"
displayed on the menu
panel in the inverse video
bar, press "ENTER" key
and the flow data screen
appears.
Maximum three data items
can be displayed on one
screen.
Executing Function Key
F1 : Updates the current data.
F2 : Displays the self-check
screen.
F3 : Displays the parameter
print sreen.
F4 : Returns to the previous
panel. (menu panel)
F040503.EPS
● Function key
The functions of the function keys vary with the commands
being displayed on the display panel.
Table 4.4
Command
ADJ
Calls up the adjustment menu.
CAPS/caps
Changes the uppercase / lowercase mode.
CLR
Clears entered data / deletes all data.
COPY*
Prints parameters on the screen.
DATA
Updates parameter data.
DEL
Deletes one character.
DIAG
Calls up the self-check screen.
ESC
Returns to the preceding screen.
FEED*
Paper feed.
Calls up the home menu (A : DISPLAY).
HOME
LIST*
Prints all parameters of the menus.
NO
Setting stop / re-setting. Returns to the
previous screen.
OK
Goes to the next screen.
PARM
Parameter number setting mode.
PON/POFF*
Printer output of data whose setting was
changed Mode on / off.
PRNT*
Changes to the prints mode.
SET
Calls up the setting menu (B : SETTING).
SLOT
Returns to the slot selection screen.
GO*
Starts print out.
STOP*
Stops printing.
UTIL
Transfers to the utility screen.
*The command is available only for BT-200-P00
4-10
4. BASIC OPERATING PROCEDURES
Description
IM 01F06A00-01E
T040501.EPS

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents