YOKOGAWA DAQSTATION DX100 Technical Information
YOKOGAWA DAQSTATION DX100 Technical Information

YOKOGAWA DAQSTATION DX100 Technical Information

Paperless recorder
Hide thumbs Also See for DAQSTATION DX100:

Advertisement

Quick Links

Technical
Information
TI 04L01A01-02E
DAQSTATION
DX100/DX200
TI 04L01A01-02E
©Copyright Feb. 2000
2nd Edition Feb. 2000

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DAQSTATION DX100 and is the answer not in the manual?

Questions and answers

Summary of Contents for YOKOGAWA DAQSTATION DX100

  • Page 1 Technical DAQSTATION Information DX100/DX200 TI 04L01A01-02E TI 04L01A01-02E ©Copyright Feb. 2000 2nd Edition Feb. 2000...
  • Page 2: Table Of Contents

    Modbus is a registered trademark of AEG Schneider Automation GmbH. Zip is a trademark or registered trademark of Iomega Corporation. Other company and product names are trademarks or registered trademarks of their respective holders. All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 3: Introduction

    Rugged construction for high reliability "Reliability that exists even in the toughest conditions." YOKOGAWA takes pride in providing the most reliable products. All measured data are stored to the flash memory, which does not require battery backup. In addition, measured data are periodically stored to the external recording medium and, at the same time, measurement data files are automatically transferred to an FTP server.
  • Page 4: Overview Of Functions

    DX200 a. Navigation key b. Soft key c. [START] key d. [STOP] key e. [USER] key f. [FUNC] key g.[ESC] key h [MENU]key i. Keyboard display(DX100) j. Key panel(DX200) All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 5: Run Mode

    Standard Internal memory Removable computation storage media Filter Standard Function Optional Function Computation / Report Alarm function Security function Batch function Remote control Alarm relay output Ethernet Serial Communication All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 6: Input Unit

    Off, up, or down can be selected for each channel. : Select whether or not to use the internal compensation circuit to carry out reference junction compensation (Internal/External) for thermocouple(TC) inputs for each channel. All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 7: Standard Calculation Functions

    Low-pass filter Calculating Average of 5 Most Recent Samples. 2.2.4 Tag Names A tag name can be set for each channel. Tag name : Up to 16 alphanumeric characters All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 8: Display Section

    1 or 2 channels DX100 channels channels 1 to 4 channels DX200 channels channels Display example) Display Optimization on the DX200 10 channels / 1 group 4 channels / 1 group All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 9: Status Display

    The data file stored in external media can be seen as a historical data. You can also display the historical waveform of the display data while displaying the current waveform. All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 10 Span bandwidth : 5% or greater (display span of the waveform) Resolution : 1% (0 to 100%) Zone 1 Zone 2 Normal display Zone display All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 11 Trend display screen DX100 DX200 ①Digital display part ②Trip line ③Scale display ④Time information ⑤Message a. Numeric indications b. Trip line c. Current value pointer d. Time information e. Message All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 12 <Toc> <Ind> Samples of trend display(DX100) Scale:Off/Numeric display:Off Scale:Off/Numeric display:Off Scale:On/Numeric display:Off Scale:On/Numeric display:Off Scale:Off/Numeric display:On Scale:Off/Numeric display:On Scale:On/Numeric display:On Scale:On/Numeric display:On All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 13 <Toc> <Ind> Samples of trend display(DX200) Scale:Off/Numeric display:Off Scale:Off/Numeric display:Off Scale:On/Numeric display:Off Scale:On/Numeric display:Off Scale:Off/Numeric display:On Scale:Off/Numeric display:On Scale:On/Numeric display:On Scale:On/Numeric display:On All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 14 0.0). Example 5 If the scale is set to -0.0005 to 0.5000, the upper and lower limits of the scale are displayed as 0.00 to 0.50 All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 15 0.0, or 0.00). Example 5 If the scale is set to -0.0005 to 0.5000, the upper and lower limits of the scale are displayed as 0.00 to 0.50 All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 16 Delayed high limit alarm Delayed low limit alarm Green box : Alarm released Red box : Alarm in effect When Alarm Indication Hold is selected, it blinks until Alarm Ack is executed. All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 17 : Displayed in green when the alarm is released, red when the alarm is in effect. f. Measured value : Displayed in red when the alarm is in effect. All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 18 You can use the cursor to specify a channel and display the trend or bar graph containing that channel. Overview display OVERVIEW DX100 DX200 a. Cursor b. Channel number or Tag name c. Current value d. Alarm type All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 19 Time of alarm occurrence d. Time of alarm release : Alarm in effect Green : Alarm released Messagr summary display DX100 DX200 a Message b. Date and time of message entry All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 20 <Toc> <Ind> Memory summary DX100 DX200 a. Data saving start/stop time b. Number of data c. Factor : Indicates a factor of file generation. All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 21 : Up to 16 alphanumeric characters Storage method : Store using the soft keys in the operation mode Recall : Select the desired configuration using the operation keys Four screen display (DX200) All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 22: Waveform Reference Function (Historical Trend Display)

    Max. and Min. values of display range. ① Two screen display(display data file) a. Historical data b. Current waveform c. Numeric display section The current value is displayed. All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 23 Historical trend display of display data file saved in removable storage media Historical trend of Display data file, saved in media in set mode, can be displayed on DX. All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 24: Recording Section

    : Serial number (0 to 9,A to Z) Setup file name The name of the setup file is specified using up to eight alphanumeric characters. Setup file : xxxxxxxx.PNL (xxxxxxxx: eight or less alphanumeric characters) All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 25: Description Of Files

    Waveform Display speed (Approx.) 1min/div 2sec 615.0mm/h 2min/div 4sec 307.5mm/h 5min/div 10sec 123.0mm/h 10min/div 20sec 61.5mm/h 20min/div 40sec 30.7mm/h 30min/div 1min 20.5mm/h 1hr/div 2min 10.2mm/h 2hr/div 4min 5.1mm/h 4hr/div 8min 2.5mm/h All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 26 Pretrigger When the trigger occurs, you can have the data before the trigger is written to the memory. Pretrigger : Select from 0, 5, 25, 50, 75, 95, and100% All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 27 *Number of sets : One sets consists of one START and one STOP. The storage range is either the maximum value of the number of data points or the maximum number of sets. All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 28 Setup file (.PNL) The SET mode and SETUP mode settings are stored to the medium. The settings are stored using the keys in the SET mode screen. All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 29: Recording Operation

    1, 2, 3, 5, 7, 10, 14, 31days Selectable Auto save intervals are varied by waveform update rate, file combination, or number of channels saved in internal memory. (Refer to 2.4.5 Sample time) All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 30: Sampling Time

    …4 However, 30,000 data points maximum. Sampling Time Sampling period (maximum recording period) is determined from the following equation. Sampling period = Maximum number of data points×sampling interval …5 All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 31 Maximum number of data points = 300 Kbytes/(12×2 bytes+6×4 bytes) = 6,250 data points When the event file sampling interval is 1 s Event file sampling period = 6,250 × 1 s = 6,250 s (approx. 1.7 hours) All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 32: Standard Functions

    3.1.4 Functions of the [USER] Key You can assign one of the following functions to the [USER] key. Trigger Alarm ACK Computation start/stop Computation reset Manual sampling Messages 1 to 8 Snapshot All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 33: Larm Function

    Alarm Indication on Blink in Turn on red status section Output contacts : When the alarm output relay option is installed, the alarm can be output to the relay. All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 34 Therefore, alarm does not occur. :The input exceeds the alarm level and the status last specified delay period, so alarm occurs. :Alarm is released because the input is higher than the alarm level All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 35 :During alarm delay, if calculation is stoped, alarm occur after Calculation stop specified delay period is lasted Calculation stop calculation value Alarm delay level Alarm All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 36: Ecurity Function

    [FUNC] key. To release the key lock, you will enter a password that has been set beforehand. When the key lock is released, the key lock indicator in the DX status display section turns OFF. All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 37: Key Login Function

    Only operations that are not key locked are possible operator mode Switching displays, batch screen, etc. Key lock release Key lock password All operations are possible engineering mode All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 38: Standard Specifications

    : TCP, UDP, IP, ARP, and ICMP Communication protocol The DX Series is capable of using the TCP/IP protocol. For upper layer protocols, it supports FTP for file transferring, and YOKOGAWA's proprietary protocol for monitoring. OSI 7 Layers DX Ethernet communications...
  • Page 39 Maintenance & testing service : A service that provides information that can be used to maintain and diagnose the Ethernet communications. FTP service : A service use to transfer files. Device information service : Service providing device information All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 40: Functions

    : Registers the password for the clients that will be allowed access. Up to six characters Configuration and measurement function DX can be configured, and measured data can be seen as real time monitor via Ethernet. All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 41 All information Output all information. Serial Serial Number Output serial number. Model Model name Output vender, model, and version. Host Host name Output host name. IP address Output IP address. All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 42 2. Open FTP Connection(open, <user name>, <password>) 3. Change directory(cd) 4. Specify tarnsfer mode(binary) 5. Download a file(get) 6. Disconnect FTP connection(close) 7. Quit FTP(quit) ※ Commands in parenthesis correspond to the work. All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 43 'C:\>' is DOS prompt, after execution of FTP, the prompt is changed to 'ftp>'. When FTP is specified 'debug' option, mode is changed to debug mode, and the line '--->' appear. All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 44: Network Configuration Example

    : 255.255.255.0 Default gateway : 0.0.0.0 DNS On/Off : Off DX2 network setting example IP address : 192.168.1.2 Subnet mask : 255.255.255.0 Default gateway : 0.0.0.0 DNS On/Off : Off All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 45 : xxxx (Password of User admin registered in DX) Depending on FTP tool installed, Since descriptions of host address or user ID are different depending on FTP tool installed, please confirm them before setting. All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 46 DX series to the 192.168.2.254 Router network in order to carry out centralized data storage and monitoring. Plants Connection Example using the LAN All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 47 Auto save period : 1h Display data in internal memory is saved as files in media every an hour automatically and transferred to the server automatically at the same time. All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 48 In this case, the dialup router must be configured, but you can construct a Connection Example using public line closed network using public lines. All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 49: Points To Be Noted When Configuring A Network

    DX1. (Since DX1 and DX2 are in the same collision domain, PC B cannot transmit packets to DX2.) Switch A router relays the packets (routing) according to the network address. Router Collision Domain Broadcast Domain All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 50: Network Terminology

    Set connection for the target host in advance to send/receive data. It secures reliability of data sending/receiving. UDP(User Datagram Protocol) Protocol which does not set connection for the target host. All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 51 ISDN(integrated services digital network) Total service digital communication network. Digital communication network, which provides integrated service of telephone, fax, internet and so on. All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 52: Optional Functions

    Use "1" and "0" for "H" and "L" conditions of the remote contact in the computing equation. Number of inputs : eight (D1, D2, D3, D4, D5, D6, D7, and D8) Inputs always start with the letter D (D2, for example). All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 53: Available Operators

    Set the P-P value of Ch.3 in Ch.33. Average 34 : TLOG.AVE(4) Set the average value of Ch.4 in Ch.34. Total 35 : TLOG.SUM(5) Set the total of value of Ch.5 in Ch.35. All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 54: Statistical Computation(Tlog)

    (2) Specified Intervals from When Mathematical calculation (MATH) Starts (example) (Setting) Mode : Relative Time : 2h 10:30 12:30 14:30 16:30 Start Stop calculation △ △ △ Time-up Time-up Time-up All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 55 125 ms. Setting the scale to ”/s” (per second) will calculate the correct totalized rate based on the measurement period. The following shows an example of settings for DX104. Input : Flow rate( /s) Measurement period : 125ms(8times per second) Scale : /s All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 56: Rolling Average

    The rolling average is a type of computation function that performs a moving average on the input data. It can also be used to measure the moving average of the computed result. The rolling average can be used to determine the long-term moving average. All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 57: Report Function

    • When calculation is stopped, the most recent calculation results are retained and used as the channel values for display and communication • When calculation is stopped, the alarm outputs for the computed-value channels are reset. All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 58: Applications In Which The Computation Function Is Used

    2) in computation channel CH32. When the food temperature falls to 100℃, reset the value of CH32 to 0. CH32 (computation channel): 32: (32 + 31/ K4) * (1 .GT. K5) All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 59: Setting Restrictions And Supplement Information

    The following calculations result in a calculation error and cause the calculation result to be output as “+****” (positive overflow). ・X/0 ・√-X ・LOG(-X) ・When a calculation expression contains a channel number which is set as being skipped. All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 60: Atch Function (/Bt1)

    Current time and batch name are changed every 5 seconds. Log on status Log off or not use key log in ①Log in user name ②Display group ③Current date and time All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 61: Ontact Nput Utput

    10% (auto mode). Output format : FAIL relay ; NO-C-NC (de-energizing) Memory end relay ; NO-C-NC (energizing) Contact capacity : 250 VDC/0.1 A (resistive load), 250 VAC (50/60 Hz)/3 A All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 62: Erial Communications (/C2,/C3)

    Data interval : 24 [bit time] or less The end of the message is determined by a blank time period of 3.5 characters or more. Error detection : Uses CRC-16 All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 63 C30 Digital data Because the register values do not include the unit and the decimal position information, the MODBUS master must know beforehand the unit and the decimal position. All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 64: Appendix

    23days 46days 11hr 23hr 47hr 71hr 5days 11days 23days 11hr 23hr 46hr 69hr 5days 11days 23days 10hr 20hr 41hr 62hr 5days 10days 20days 18hr 37hr 55hr 4days 9days 18days All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 65 71min 11hr 23hr 71hr 5days 11days 17min 34min 69min 11hr 23hr 69hr 5days 11days 15min 31min 62min 10hr 20hr 62hr 5days 10days 13min 27min 55min 18hr 55hr 4days 9days All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 66 69hr 4days 8days 17days 34days 17hr 35hr 53hr 4days 8days 17days 17hr 34hr 52hr 4days 8days 17days 15hr 31hr 46hr 93hr 7days 15days 13hr 27hr 41hr 83hr 6days 13days All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 67 4min 8min 17min 35min 17hr 35hr 71hr 4min 8min 17min 34min 17hr 34hr 69hr 3min 7min 15min 31min 15hr 31hr 62hr 3min 6min 13min 27min 55min 13hr 27hr 55hr All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 68 1 hr 1 day Only display data file Measurement ch:2 Computation ch:4 Waveform update rate[/DIV] Automatic saving interval 1min 2min 5min 10min 20min 30min 10 min 1 hr 1 day All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 69 1 day Display data + event data file Measurement ch:2 Computation ch:4 Waveform update rate[/DIV] Automatic saving interval 1min 2min 5min 10min 20min 30min 10 min 1 hr 1 day All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 70 1 hr 1 day Only display data file Measurement ch:4 Computation ch:4 Waveform update rate[/DIV] Automatic saving interval 1min 2min 5min 10min 20min 30min 10 min 1 hr 1 day All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 71 Waveform update rate[/DIV] Automatic saving interval 1 min 2 min 5 min 10 min 20 min 30 min 1 hr 2 hr 4 hr 10 min 1 hr 1 day All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 72 1 hr 1 day Only display data file Measurement ch:6 Computation ch:12 Waveform update rate[/DIV] Automatic saving interval 1min 2min 5min 10min 20min 30min 10 min 1 hr 1 day All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 73 1 day Display data + event data file Measurement ch:6 Computation ch:12 Waveform update rate[/DIV] Automatic saving interval 1min 2min 5min 10min 20min 30min 10 min 1 hr 1 day All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 74 1 hr 1 day Only display data file Measurement ch:12 Computation ch:12 Waveform update rate[/DIV] Automatic saving interval 1min 2min 5min 10min 20min 30min 10 min 1 hr 1 day All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 75 1 day Display data + event data file Measurement ch:12 Computation ch:12 Waveform update rate[/DIV] Automatic saving interval 1min 2min 5min 10min 20min 30min 10 min 1 hr 1 day All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 76 1 hr 1 day Only display data file Measurement ch:4 Computation ch:8 Waveform update rate[/DIV] Automatic saving interval 1min 2min 5min 10min 20min 30min 10 min 1 hr 1 day All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 77 1 day Display data + event data file Measurement ch:4 Computation ch:8 Waveform update rate[/DIV] Automatic saving interval 1min 2min 5min 10min 20min 30min 10 min 1 hr 1 day All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 78 1 hr 1 day Only display data file Measurement ch:8 Computation ch:8 Waveform update rate[/DIV] Automatic saving interval 1min 2min 5min 10min 20min 30min 10 min 1 hr 1 day All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 79 1 day Display data + event data file Measurement ch:8 Computation ch:8 Waveform update rate[/DIV] Automatic saving interval 1min 2min 5min 10min 20min 30min 10 min 1 hr 1 day All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 80 1 hr 1 day Only display data file Measurement ch:10 Computation ch:30 Waveform update rate[/DIV] Automatic saving interval 1min 2min 5min 10min 20min 30min 10 min 1 hr 1 day All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 81 1 day Display data + event data file Measurement ch:10 Computation ch:30 Waveform update rate[/DIV] Automatic saving interval 1min 2min 5min 10min 20min 30min 10 min 1 hr 1 day All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 82 1 hr 1 day Only display data file Measurement ch:20 Computation ch:30 Waveform update rate[/DIV] Automatic saving interval 1min 2min 5min 10min 20min 30min 10 min 1 hr 1 day All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 83 1 day Display data + event data file Measurement ch:20 Computation ch:30 Waveform update rate[/DIV] Automatic saving interval 1min 2min 5min 10min 20min 30min 10 min 1 hr 1 day All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 84 1 hr 1 day Only display data file Measurement ch:30 Computation ch:30 Waveform update rate[/DIV] Automatic saving interval 1min 2min 5min 10min 20min 30min 10 min 1 hr 1 day All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 85 1 day Display data + event data file Measurement ch:30 Computation ch:30 Waveform update rate[/DIV] Automatic saving interval 1min 2min 5min 10min 20min 30min 10 min 1 hr 1 day All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 86: Faq

    Is input scaling possible? Linear scaling can be set for DC voltage, thermocouple, and resistance temperature detector input ranges. The unit can be set with up to 6 characters. All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 87 The life of the LCD is determined by the life of the backlight, which is 5 years in general (but varies according to the use of the LCD saver and the brightness setting). The replacement of the LCD must be performed by Yokogawa Engineering Service Corporation or an authorized service representative.
  • Page 88 What is the data format? The measured values are Yokogawa standard, 2-byte binary data. The computed values are Yokogawa standard, 4-byte binary data. Can the parameter settings be saved The settings made in both SET and SETUP modes can be saved.
  • Page 89 Yes, it is possible by using ISDN router or dial-up router. phone line? There are various kinds of ISDN routers or dial-up routers to connect public phones for home use to company use. All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...
  • Page 90 Please convert the data to Excel or Lotus1-2-3 format and use graph functions of the different files overlapped? spreadsheet. It is also possible to display waveforms of different files in tiles on Windows. All Rights Reserved. Copyright © 2000, Yokogawa Electric Corporation TI 04L01A01-02E...

This manual is also suitable for:

Daqstation dx200

Table of Contents