9.5 Sizing

The following items are the basic specifications.
In case of the definite sizing, it is necessary to check by
the sizing software.
■ Measurable minimum flow velocity
Table 9.5.1
Relationship between Minimum Velocity and
Density (In case of "Gas, Steam", Use the
Large of the Two Values)
Model
Code
DY015
DY025-/R1
DY040-/R2
DY025
DY040-/R1
DY050-/R2
DY040
DY050-/R1
DY080-/R2
DY050
DY080-/R1
DY100-/R2
DY080
DY100-/R1
DY150-/R2
DY100
DY150-/R1
DY200-/R2
DY150
DY200-/R1
––
DY200
––
––
DY250
––
––
DY300
––
––
ρ : Density at operating conditions (kg/m
Liquid density is 400 up to 2000kg/m
(Note) Reduced bore type (/R1 and /R2) are not available to combine for Cryogenic type (/LT.)
■ Range of measurable flow velocity
Table 9.5.2 Range of measurable flow velocity
Fluid
Model Code
DY025-
DY040-
/R1
/R2
DY015
up to
up to
up to
Liquid
DY300
DY200-
DY200-
/R1
/R2
DY025-
DY040-
DY015
/R1
/R2
Gas,
up to
up to
up to
Steam
DY300
DY200-
DY200-
/R1
/R2
When the flow velocity is lower than minimum, both the analog
output and the pulse output is displayed as zero "0".
Gas, Steam
Liquid
General
General
High
Type,
Type,
Process
Cryogenic
Cryogenic
Temperature
Type
Type
Version
(unit: m/s)
(unit: m/s)
(unit: m/s)
(Note)
(Note)
250 /ρ
––
80/ρ or 3
122.5/ρ
490/ρ
45/ρ or 2
31.3/ρ or 2
90/ρ
302.5/ρ
90/ρ
160/ρ
31.3/ρ or 2
90/ρ
160/ρ
31.3/ρ or 2
90/ρ
160/ρ
31.3/ρ or 2
31.3/ρ or 3
90/ρ
160/ρ
122.5/ρ
202.5/ρ
45/ρ or 3
160/ρ
––
61.3/ρ or 3
61.3/ρ or 3
160/ρ
––
3
)
3
Maximum
flow
Minimum flow velocity
velocity
(Note)
"flow velocity obtained from
Table 9.5.1" or "flow velocity
at Reynolds number of
10 m/s
5000", whichever is greater.
For liquid Reynolds number
of 5000 : See P.9-16
"Calculation formula".
"flow velocity obtained from
Table 9.5.1" or "flow velocity
at Reynolds number of
5000", whichever is greater.
80 m/s
For Gas and steam
Reynolds number of 5000 :
See P.9-16 "Calculation
formula".
DYF Tab-11
Steam
High
Process
Temperature
version
(unit: m/s)
––
125/ρ or 2
90.3/ρ or 2
61.3/ρ or 2
61.3/ρ or 2
61.3/ρ or 2
61.3/ρ or 3
80/ρ or 3
––
––
DYF Tab-10
■ Range of fixed accuracy flow velocity
Table 9.5.3 Range of fixed accuracy flow velocity
Fluid
Model Code
DY025-
DY015
/R1
up to
up to
DY100
DY150-
/R1
Liquid
DY150
DY200-
up to
/R1
DY300
DY025-
DY015
/R1
up to
up to
DY100
DY150-
/R1
Gas,
Steam
DY150
DY200-
up to
/R1
DY300
9-15
9. GENERAL DESCRIPTION
Minimum flow velocity
"flow velocity obtained from
Table 9.5.1" or
DY040-
"flow velocity at Reynolds
/R2
number of 20000", whichever
up to
is greater.
For liquid Reynolds number
DY200-
of 20000 : The value is four
/R2
times velocity value in P.9-16
"Calculation formula".
"flow velocity obtained from
Table 9.5.1" or
"flow velocity at Reynolds
number of 40000", whichever
is greater.
For liquid Reynolds number
of 40000 : The value is eight
times velocity value in P.9-16
"Calculation formula".
"flow velocity obtained
fromTable 9.5.1" or
DY040-
"flow velocity at Reynolds
/R2
number of 20000",
up to
whichever is greater.
For gas and steam
DY200-
Reynolds number of 20000 :
/R2
See P.9-16 "Calculation
formula".
"flow velocity obtained
fromTable 9.5.1" or
"flow velocity at Reynolds
number of 40000",
whichever is greater.
For gas and steam
Reynolds number of 40000 :
See P.9-16 "Calculation
formula".
IM 01F06A00-01E
Maximum
flow
velocity
(Note)
10 m/s
80 m/s
DYF Tab-12