The product is provided on an “as is” basis. YOKOGAWA shall have neither liability nor responsibility to any person or entity with respect to any direct or indirect loss or damage arising from using the product or any defect of the product that YOKOGAWA can not predict in advance. IM 19H1D2-01E...
Page 5
<INTRODUCTION> n Symbol Marks Throughout this user’s manual, you will find several different types of symbols are used to identify different sections of text. This section describes these icons. WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
If we replace the product with a new one, we won’t provide you with a repair report. l Yokogawa warrants the product for the period stated in the pre-purchase quotation Yokogawa shall conduct defined warranty service based on its standard. When the customer site is located outside of the service area, a fee for dispatching the maintenance engineer will be charged to the customer.
3.3 Installation ......................3-4 3.3.1 Selecting Measurement Point ............3-4 3.3.2 Selecting a Place of Installation for the DOX8HS Submersion Type Holder ..................3-4 3.3.3 Securing DOX8HS Submersion Type Holder ........3-4 3.3.4 Installing DOX8HS Submersion Type Holder ........3-4 3.4...
< 1. Overview > Overview 1.1 Features of the DOX8HS Submersion Type Holder • Holds the sensor in place without being affected by the conditions of the solution to be measured The sensor is steadily held at the measurement point no matter how fast the solution flows.
Air jet 100 to 200 10 to 20 Nl/min (Note 1) Pressure and flow rate must be simultaneously satisfied at the holder inlet port. (Note 2) A large braid-reinforced tube of Ø22 x Ø15 is recommended for supply due to the flow rate. 1.2.2 Model and Suffix codes Model Suffix Code Description Option Code ..............Submersion type holder DOX8HS Material ....Polypropylene ....Stainless steel ....Pipe length 1.0 m ....1.5 m ....
*2: The required number of mounting bracket sets depends on the installation location and flow rate. In general, one set is sufficient for pipe lengths of 1 meter, and otherwise two sets are required. *3: When -JT (For jet cleaning) is specified, select Rc1/2 or 1/2NPT of Connector for Cleaning. When DO71, DO72 and DO70 connect to holder, adapter is used. /D71P, /D72P can be selected when suffix code of “-PP (Polypropylene)” specified. /D72S, /D72S can be selected when suffix code of “-S3 (Stainless steel)” specified. 1.2.3 External Dimensions DOX8HS-PP-¨¨-C (Polypropylene) (For DO30G and SS300G) Unit: mm <With Jet cleaner> <Without cleaner> 1/2 NPT 35 48 (Code: NP) Rc1/2 44 64 (Code: JP) 44 64...
< 2. Names and Functions > Names and Functions Holder with washing device Holder without washing device Adapter Drip-proof cap Pipe for washing utility; Leads the cable downwards supplied when 1/2 NPT and prevents rain from entering is specified. the bolder. Clamp (Sensor holder) Sensor holder Secures the sensor holder...
3.1 Installation procedure for the DO71 sensor to DOX8HS Pass GLAND from the cable side and place the bottom of the sensor on GLAND as shown in the posture of the Figure 3.1. Remove the protective cover put on the head of the sensor. Pass WASHER, GASKET, WASHER, ADAPTER from the head of the sensor side.
< 3. Installation, Piping and Wiring > 3.2 Preparations for lnstallation 3.2.1 Inserting the Sensor Insert the sensor when the submersion type holder is installed. SEE ALSO Information regarding sensor orientation and other details differ with the sensor used. Refer to the user’s manual of the sensor. Insert the sensor according to the following instructions.
< 3. Installation, Piping and Wiring > 3.2.2 Inserting the Mounting Bracket The submersion type holder is used attached to 2-inch pipe (outer diameter 60.5 mm). Pipe mounting brackets (see Figure 1.4) are supplied when specified and should be used in the installation. As a rule, one set of brackets is provided for a 1.0 m holder and 2 sets for a 1.5 m long or more holder.
Selecting a Place of Installation for the DOX8HS Submersion Type Holder Sensors must be calibrated and maintained regularly. Thus the DOX8HS submersion type holder should be installed in a location that satisfies the following conditions. • Space enough to allow calibration and maintenance near the measurement point •...
The solenoid valve in the washing pipe line should be 15 A aperture (pipe joint port) that operates normal close (that closes when electrified). Yokogawa provides solenoid valves with the following specifications. [Model PH8MV Solenoid Valve] Pilot kick operated, 2-port valve. Open when energized.
< 3. Installation, Piping and Wiring > 3.4.2 Piping Examples (1) Air Jet Washing Contact signal (from converter) Power supply Pressure regulator Air supply Solenoid Pressure: 2 MPa or less valve JIS 15 A hard pipe JIS 16 A net-impregnated soft polyvinyl chloride resin tube Note: Adjust the secondary pressure of the pressure regulator to between 100 and 200 kPa.
< 3. Installation, Piping and Wiring > 3.3.3 Wiring Normally, washing is executed when a "cleaning" contact signal is received from the converter. Note: The contact output must be set to "cleaning" function. For details, refer to the user’s manual supplied with each converter. Install wiring so that when the contact signal is output drive power is supplied to the solenoid valve (or pump), and utility (air or water flows into the washing device).
< 4. Maintenance > Maintenance When the DOX8HS submersion type holder operates normally, maintenance and inspections need not be performed. Perform inspection and maintenance procedures described in this chapter in conjunction with calibration and sensor maintenance. 4.1 Inspecting Sensor Retaining O-ring The sensor is designed such that it can be immersed in the solution up to the sensor cable and the entry of solution in the holder does not lead to a breakdown.
< 4. Maintenance > 4.2 Inspecting the Cleaning Device The following information concerns only the submersion type holder with jet washing device. SEE ALSO For maintenance of the MLSS sensor with wiper-washing, refer to the MLSS sensor's mamual. Make the following inspections of the device. Check the nozzle of the jet washing device for clogging.
P.i, Introduction, “ 2. Contents” Table: Added of the DO70G optical dissolved oxygen sensor; P.1-1, Section 1.1, “ Features of the DOX8HS Submersion Type Holder” Figure 1.1: Added of the figure; P.1- 2, Section 1.2.1, “ Standard Specifications” Applicable sensors: Added of the DO70G optical dissolved oxygen sensor.
Need help?
Do you have a question about the DOX8HS and is the answer not in the manual?
Questions and answers