10.2.5 Installation Diagram

Intrinsically Safe (and WARNING)
Hazardous Location
Class I, II, III, Division 1,
Groups A, B, C, D, E, F and G,
and Class I, Zone 0, Group IIC
[Integral type]
DY (flowmeter)
[Remote type]
DY-N (flowmeter)
DYA (converter)
A
A
B
B
T
T (*1)
C
DYC: Signal cable
(*1) Wire for T terminal
With temperature sensor type
Without temperature sensor type: not installed
Electrical parameters of vortex flowmeter (DY) and vortex flow
converter (DYA).
Vmax=30V
Imax=165mA
Ci=12nF
Li=0.15mH
Installation requirement between flowmeter, converter and
Safety Barrier
Vt or Voc
Vmax It or Isc
Ca
Ci+Ccable
La
Li+Lcable
Vt, Voc, It, Isc, Voc, Ca and La are parameters of barrier.
WARNING
• In any safety barrier used output current must
be limited by a resistor 'R' such that Isc=Voc/R.
• Any Single FM Approved Barrier of multiple
barriers FM Approved for this configuration
who's parameters meet the above installation
requirements.
• Input voltage of the safety barrier must be less
than 250Vrms/Vdc.
• Installation should be in accordance with
National Electrical Code, ANSI /NFPA70.
• Dust-tight conduit seal must be used when
installed in class II and III environments.
• Do not alter drawing without authorization from
FM.
Non Hazardous
Location
Safety barriers
SUPPLY
PULSE
Safety barriers
SUPPLY
PULSE
: installed
Pi=0.9W
Imax Po
Pi
F100201_1.EPS
10. EXPLOSION PROTECTED TYPE INSTRUMENT
Nonincendive (and WARNING)
Hazardous Location
Class I, II, Division 2,
Groups A, B, C, D, F and G,
Class III, Division 1, and
Class I, Zone 2, Group IIC
[Integral type]
[Remote type]
DY-N (flowmeter)
A
B
T
DYC: Signal cable
(*1) Wire for T terminal
With temperature sensor type
Without temperature sensor type: not installed
Non-incendive field wire parameters of vortex flowmeter (DY)
and vortex flow converter (DYA).
Vmax=30V
Imax=165mA
Ci=12nF
Li=0.15mH
Installation requirement between flowmeter, converter and
general purpose equirement.
Vt or Voc
Vmax It or Isc
Ca
Ci+Ccable
Vt, Voc, It, Isc, Po, Ca and La are nonincendive field
wire parameters of general purpose equipment.
WARNING
• The general purpose equipment must be FM
approved with Nonincendive field wiring param-
eter which meet the above installation require-
ments.
• Installation should be in accordance with
National Electric Code, ANSI/NFPA70.
• Dust-tight conduit seal must be used when
installed in class II and III environments.
• Do not alter drawing without authorization from
FM.
10-6
Non Hazardous
Location
+
DY (flowmeter)
SUPPLY
PULSE
+
+
DY (converter)
A
SUPPLY
B
T
(*1)
PULSE
+
C
: installed
Pi=0.9W
Imax
Po
Pi
La
Li+Lcable
IM 01F06A00-01E
+
+
Power
Supply
+
+
Receiver
+
+
Power
Supply
+
+
Receiver
F100201_2.EPS