Model And Suffix Codes - YOKOGAWA DY025 User Manual

Digitalyewflo vortex flowmeter dy series vortex flow converter dya series
Hide thumbs Also See for DY025:
Table of Contents

Advertisement

9.3 Model and Suffix Codes

DY Vortex Flowmeter (Integral Type, Remote type detector)
Model
Suffix Codes
.................................
DY015
.................................
DY025
.................................
DY040
.................................
DY050
.................................
DY080
.................................
DY100
.................................
DY150
.................................
DY200
.................................
DY250
.................................
DY300
-D ..............................
Output
-E ..............................
Signal
/Commu-
-F ..............................
nication
*1, *12
-N ..............................
...........................
Body
A
...........................
Material
B
...........................
*2, *14
X
.....................
L
Shedder bar
.....................
E
Material *4, *14
.....................
X
AJ1 ..................
AJ2 ..................
AJ4 ..................
AA1 ..................
AA2 ..................
AA4 ..................
AD1 ..................
AD2 ..................
AD3 ..................
AD4 ..................
Process
BJ1 ..................
Connection
BJ2 ..................
*5
BJ4 ..................
BA1 ..................
RF : Raised Face
BA2 ..................
SF : Smooth Finish
BA4 ..................
RJ : Ring Joint
BA5 ..................
BS1 ..................
BS2 ..................
BS4 ..................
BS5 ..................
BD1 ..................
BD2 ..................
BD3 ..................
BD4 ..................
CA4 ..................
CA5 ..................
Electrical
-0...................
Connection *11
-2...................
-4...................
Indicator
D ...............
*7
N ................
Options
/
Description
Size 15 mm (1/2 inch)
Size 25 mm (1 inch)
Size 40 mm (1-1/2 inch)
Size 50 mm (2 inch)
Size 80 mm (3 inch)
Size 100 mm (4 inch)
Size 150 mm (6 inch)
Size 200 mm (8 inch)
Size 250 mm (10 inch)
Size 300 mm (12 inch)
4 to 20 mA DC, Pulse,
BRAIN Communication
4 to 20 mA DC, Pulse,
HART Communication
Digital communication
(F
Fieldbus protocol)
OUNDATION
Remote type detector
JIS SCS14 A *10
ASTM, ASME CF8M *3
Others
Duplex stainless steel
Duplex stainless steel (for TIIS Approval)
Others
JIS 10 K Wafer
JIS 20 K Wafer
JIS 40 K Wafer
ANSI Class 150 Wafer
ANSI Class 300 Wafer
ANSI Class 600 Wafer
DIN PN10 Wafer
DIN PN16 Wafer
DIN PN25 Wafer
DIN PN40 Wafer
JIS 10K Flange(RF)
JIS 20K Flange(RF)
JIS 40K Flange(RF)
ANSI Class 150 Flange(RF)
ANSI Class 300 Flange(RF)
ANSI Class 600 Flange(RF)
ANSI Class 900 Flange(RF)
ANSI Class 150 Flange(RF, SF)
ANSI Class 300 Flange(RF, SF)
ANSI Class 600 Flange(RF, SF)
ANSI Class 900 Flange(RF, SF)
DIN PN10 Flange(RF)
DIN PN16 Flange(RF)
DIN PN25 Flange(RF)
DIN PN40 Flange(RF)
ANSI Class 600 Flange(RJ)
ANSI Class 900 Flange(RJ)
JIS G 1/2 Female
ANSI 1/2 NPT Female *6
ISO M20 1.5 Female
With Indicator
None Indicator, Remote type detector
Refer to Option Specifications
T090301.EPS
DYA Vortex Flowmeter Converter(Remote Type)
Model
Suffix Code
....................................
DYA
-D ..............................
Output
Signal
-E ..............................
/Commu-
nication
-F ..............................
*1, *12
0 ........................
Electrical
2 ........................
Connection
4 ........................
D ..................
Indicator
N ..................
/
Options
/MV ............
DYC Signal Cable
Model
Suffix Code
.................................... Signal Cable
DYC
-0 ....................................
Cable
-1 ....................................
End
-05 ..............................
-10 ..............................
-15 ..............................
-20 ..............................
-25 ..............................
-30 ..............................
-35 ..............................
-40 ..............................
-45 ..............................
Cable
-50 ..............................
Length
-55 ..............................
*9
-60 ..............................
-65 ..............................
-70 ..............................
-75 ..............................
-80 ..............................
-85 ..............................
-90 ..............................
-95 ..............................
/C1 ........................
Options
/C2 ........................
/C3 ........................
/C4 ........................
/C5 ........................
/C6 ........................
/C7 ........................
/C8 ........................
/C9 ........................
/MV ........................
* 1 : Nominal size, Fluid(Liquid, Gas, Steam), Density, Viscosity, Pressure,
Temperature, Flow range, Parameters are set at the factory before
shipment.
* 2 : Refer to Table 9.3.1.
In case of /NC or /HX or /HY or /HT or /LT, select X (others).
* 3 : In case of B (ASTM, ASME CF8M), the process connection is available
for ANSI (AA1 to 4, BA1 to 5, CA4 to 5) and DIN (BD1 to 4).
* 4 : Refer to Table 9.3.1.
In case of /NC or /HX or /HY or /HT or /LT, select X (others).
* 5 : Refer to Table 9.3.2.
* 6 : In case of /FF1 or /CF1, the screw length is deeper than ANSI standard
for 0.5 to 3.5 threads.
* 7 : Indicator is not available for remote type detector.
* 8 : One set of end finish part is attached.
* 9 : DYC cable can be used up to 30m. When you divide the cable below
30m, select the Cable End code [-0].
*10 : In case of A (JIS SCS14A), the process connection is available for JIS
(AJ1, AJ2, AJ4, BJ1, BJ2, BJ4)
*11 : In case of an explosion proof type, it depends for an electrical
connecion on the kind of an explosion protect type. Refer to 9.4.3
Option Specification (For Explosion Protected type).
*12 : For F
Fieldbus protcol, refer to GS 01F06F01-01E.
OUNDATION
For Fieldbus communication type, there are not setting keys on the
display board.
*13 : DYA-
/ MV and DY
*14 : Users must consider the characteristics of selected wetted parts material
and the influence of process fluids. The use of inappropriate materials
can result in the leakage of corrosive process fluids and cause injury to
personnel and/or damage to plant facilities. It is also possible that the
instrument itself can be damaged and that fragments from the
instrument can contaminate the user's process fluids.
Be very careful with highly corrosive process fluids such as hydrochloric
acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-
temperature steam (150°C [302°F] or above). Contact Yokogawa for
detailed information of the wetted parts material.
9-5
9. GENERAL DESCRIPTION
Description
Vortex Flowmeter Converter
(Remote Type)
4 to 20 mA DC, Pulse
BRAIN Communication
4 to 20 mA DC, Pulse
HART Communication
Digital communication
(F
Fieldbus protocol)
OUNDATION
JIS G 1/2 Female
ANSI 1/2 NPT Female *6
ISO M20 ×1.5 Female
With Indicator
None Indicator
Refer to Option Specifications
Multi-Variable Type *13
Description
Without End finish *8
With End finish
5 m
10 m
15 m
20 m
25 m
30 m
35 m
40 m
45 m
50 m
55 m
60 m
65 m
70 m
75 m
80 m
85 m
90 m
95 m
Cable End Finish Parts 1 set
2 set
3 set
4 set
5 set
6 set
7 set
8 set
9 set
Multi-variable Type
-N*** / MV should be combined.
T090302.EPS
IM 01F06A00-01E

Hide quick links:

Advertisement

Table of Contents
loading