Troubleshooting Microsoft NLB Unicast Mode

S e n d d o c u m e n t c o m m e n t s t o n e x u s 1 k - d o c f e e d b a c k @ c i s c o . c o m .
Troubleshooting Microsoft NLB Unicast Mode
Microsoft Network Load Balancing (MS-NLB) is a clustering technology offered by Microsoft as part
of the Windows server operating systems. Clustering enables a group of independent servers to be
managed as a single system for higher availability, easier manageability, and greater scalability.
For more information about Microsoft Network Load Balancing. See this URL:
http://technet.microsoft.com/en-us/library/bb742455.aspx
Access to third-party websites identified in this document is provided solely as a courtesy to customers
Note
and others. Cisco Systems, Inc. and its affiliates are not in any way responsible or liable for the
functioning of any third-party website, or the download, performance, quality, functioning or support of
any software program or other item accessed through the website, or any damages, repairs, corrections
or costs arising out of any use of the website or any software program or other item accessed through the
website. Cisco's End User License Agreement does not apply to the terms and conditions of use of a
third-party website or any software program or other item accessed through the website.

Limitations and Restrictions

A syslog is generated if one of the following configurations exists when you try to disable automatic
static MAC learning for MS-NLB because they do not support this feature:

Disabling Automatic Static MAC Learning on vEthernet

You must disable automatic static MAC learning before you can successfully configure NLB on
vEthernet (vEth).
In interface configuration mode use the following commands:
switch(config)# int veth 1
switch(config-if)# no mac auto-static-learn
In port profile configuration mode use the following commands:
switch(config)# port-profile type vethernet ms-nlb
switch(config-port-prof)# no mac auto-static-learn

Checking Status on a VSM

If the NLB unicast mode configuration does not function, check the status of the Virtual Supervisor
Module (VSM).
Confirm that no mac auto-static-learn is listed in the vEth and/or port profile configurations.
Cisco Nexus 1000V Troubleshooting Guide, Release 4.2(1)SV2(2.1)
11-12
PVLAN port
Ports configured with unknown unicast flood blocking (UUFB)
Ports configured with switchport port-security mac-address sticky