VSM and VEM Troubleshooting Commands
S e n d d o c u m e n t c o m m e n t s t o n e x u s 1 k - d o c f e e d b a c k @ c i s c o . c o m .
Example 7-2
n1000v# show svs connections
connection vc:
ip address: 172.23.231.223
protocol: vmware-vim https
certificate: user-installed
datacenter name: hamilton-dc
DVS uuid: 92 7a 14 50 05 11 15 9c-1a b0 f2 d4 8a d7 6e 6c
config status: Disabled
operational status: Disconnected
Example 7-3
n1000v# show svs domain
SVS domain config:
Domain id:
Control vlan: 3002
Packet vlan:
L2/L3 Control VLAN mode: L2
L2/L3 Control VLAN interface: mgmt0
Status: Config push to VC successful
Example 7-4
n1000v# show port-profile name SystemUplink
port-profile SystemUplink
description:
type: ethernet
status: enabled
capability l3control: no
pinning control-vlan: -
pinning packet-vlan: -
system vlans: 114,115
port-group: SystemUplink
max ports: 32
inherit:
config attributes:
switchport mode trunk
switchport trunk allowed vlan all
system mtu 1500
no shutdown
evaluated config attributes:
switchport mode trunk
switchport trunk allowed vlan all
no shutdown
assigned interfaces:
Example 7-5
n1000v# show running-config vlan 260-261
version 4.0(4)SV1(3)
vlan 260
name cp_control
vlan 261
name cp_packet
n1000v#