Fault
No detergents drawn in

9 Further information

9.1

Recycling the cleaner

9.2

Guarantee

9.3
EU Declaration
of Conformity
Options / model variants
1)
Original instructions
Cause
Detergent tank empty
The cap on the FlexoPower-
Plus nozzle head is not set to
low pressure
Double lance are not adju-
sted to low pressure.
Injector is dirty or suction
hose is blocked.
Make the old cleaner unusable immediately.
1. Unplug the cleaner and cut the power cord.
Do not discard of electrical appliances with household waste.
As specified in European Directive 2012/19/EU on old electrical and
electronic appliances, used electrical goods must be collected sep-
arately and recycled ecologically. Contact your local authorities or
your nearest dealer for further information.
Our general conditions of business are applicable with regard to the
guarantee.
Subject to change as a result of technical advances.
Nilfi sk A/S
Kornmarksvej 1
DK-2605 Broendby
DENMARK
Hereby declare that the
Products: HPW - Professional - Mobile - El
Description: 220V/440V, 230/400V, 230V, 400V, 200V, 50/60Hz, IPX5
Type: MC 5M, MC 6P, MC 7P
Are in compliance with the following standards:
EN 60335-1:2012+A11:2014
EN 60335-2-79:2012
EN 55014-1:2006+A1:2009+A2:2011
EN 55014-2:1997+A1:2001+A2:2008
EN 61000-3-2:2006+A1:2009+A2:2009
EN 61000-3-11:2000
Following the provisions of:
2006/42/EC
2014/30/EC
2000/14/EC – Conformity assessment procedure according to Annex V.
- Measured noise level: 68-80 dB(A);
- Guaranteed noise level: 82-93 dB(A)
Hadsund, 23-6-2016
Anton Sørensen, Senior Vice President, Global R&D
Remedy
Top up detergent tank
Set to low pressure
Set to low pressure
Clean
MC 5M - MC 6P - MC 7P