Mounting The Solar Panel (Integral Mount) - Emerson FB1200 Instruction Manual

Flow computer
Hide thumbs Also See for FB1200:
Table of Contents

Advertisement

7
8
2.12.2

Mounting the Solar Panel (Integral Mount)

DANGER
EXPLOSION HAZARD: Ensure the area in which you perform this operation is non-hazardous.
Performing this operation in a hazardous area could result in an explosion.
Restriction
The solar panel and lead acid battery combination cannot be used with ATEX/IECEx applications.
The integral mount solar panel cannot be used in a Class I Division 1 area; C1D1 solar panels must
be remote mounted with the solar panel in a safe area.
1. Apply Loctite
Attach elbow pipe (Item 15) to the flow computer conduit opening (Item 16); torque to 50 in-
lbs (5.6 N m).
2. Apply Loctite 380 adhesive sparingly to threads of pipe (Item 14).
3. Attach pipe (Item 14) to elbow pipe (Item 15). Torque to 50 in-lbs (5.6 N m).
4. Attach pipe cap (Item 11) to top of pipe (Item 14). Torque to 50 in-lbs (5.6 N m).
5. Apply Loctite 222 threadlocker sparingly to threads of U-bolt (Item 12).
6. Attach solar panel assembly to pipe (Item 14) using U-bolt (Item 12).
7. Adjust swivel and tilt angle for maximum solar exposure (see Section 2.13.5).
Installation
5/16 flat spring lock washer (2) only one visible; placed on bolt between washer and
nut
mounting bracket
®
380™ Black Instant Adhesive to threads of elbow pipe (Item 15 in Figure 2-20).
Emerson FB1200 Flow Computer Instruction Manual
D301782X012
July 2017
33

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents