Figure 2-12: Proper Bolt Installation
1
2
2.7.2

O-rings with Flange Adapters

DANGER
Failure to install proper flange adapter O-rings may cause process leaks, which can result in death
or serious injury. Only use the O-ring that is designed for its specific flange adapter.
Figure 2-13: O-rings with Flange Adapters
1
2
3
4
1.
Whenever the flange or adapters are removed, visually inspect the O-rings.
2.
Replace the O-rings if there are any signs of damage, such as nicks or cuts.
3.
If the O-rings are replaced, re-torque the flange bolts and alignment screws after installation
to compensate for seating of the O-rings.
20
Bolt
Sensor module
Flange
O-ring
Square PTFE-based profile