Communicating With A Laptop Using One Of The Serial Ports; Communicating With A Laptop Using Ethernet - Emerson FB1200 Instruction Manual

Flow computer
Hide thumbs Also See for FB1200:
Table of Contents

Advertisement

Emerson FB1200 Flow Computer Instruction Manual
D301782X012
July 2017
1.
2.
3.
Provide the SCADA host with information about the various parameters it needs to extract
from the application running in the flow computer. Typically, the SCADA host software
includes a utility that allows you to identify this information so it can be incorporated into the
database at the SCADA host.
4.
Using whatever human-machine interface (HMI) tools exist for the SCADA host, create
graphical displays or reports that include the parameters from the application required for
successful operator interaction (setpoints, flow variables and so on).
4.2.2

Communicating with a Laptop Using One of the Serial Ports

If the flow computer is not awake, you must wake it up first. (See Section 4.3)
Your laptop must have Field Tools software with FBxConnect software installed.
You must know a valid username/password combination for the flow computer.
DANGER
EXPLOSION HAZARD: Ensure the area in which you perform this operation is non-hazardous.
Performing this operation in a hazardous area could result in an explosion.
1.
Connect a cable between a serial port (or serial/USB adapter) on your laptop and port COM2
on the flow computer.
2.
Launch Field Tools and add a new serial connection for this device; this launches FBxConnect
configuration software. (If you already have an existing saved serial connection for this
device in Field Tools, just double-click on it in the Connections list.)
3.
Log into the flow computer if prompted.
4.
Use the FBxConnect configuration software to view or change any desired parameters.
5.
When finished, log off the flow computer and disconnect the cable from its serial port.
4.2.3

Communicating with a Laptop Using Ethernet

Your laptop must have Field Tools software with FBxConnect software installed.
You must know a valid username/password combination for the flow computer.
70
Decide how the SCADA host should communicates with the flow computer. This could be
through connection with one of the communication ports. A serial port connection could
be a cable directly connected to the SCADA host or there could be intermediate
connections through a radio or modem. An Ethernet port connection must be through an
Ethernet switch with an appropriate Category 5 shielded patch cable.
Decide which communication protocol you will use. This could be DNP3, ROC, or BSAP.
See these documents for more information:
Emerson FB Flow Computer DNP3 Protocol Specifications Manual (D301806X012)
ROC Protocol Specifications Manual (for Emerson FBx-series) (D301828X012)
FB1x00/FB2x00 BSAP Communication Guide (D301808X012)