Hydraulic Resistance - IDEAL Viceroy GT 8 Installation And Servicing

Hide thumbs Also See for Viceroy GT 8:
Table of Contents

Advertisement

Table 1 Performance Data
Boiler
Number of Sections
Maximum
Heat Output
Minimum
Heat Output
Hydraulic
Resistance at 11k
Hydraulic
Resistance at 20k
Combustion Chamber
Resistance (at zero draught)
Minimum Draught at Smokehood mbar
Outlet (for max. output)
Oil
Maximum
Oil Rate
Maximum Flue
Gas Volume
Flue Gas CO
/ Temperature
2
Gas
Maximum
Gas Rate
Maximum Flue
Gas Volume
Flue Gas CO
/ Temperature
2
Table 2 General Data
Flow Connection
Return Connection
Drain Connection
Maximum Operating Pressure
Boiler Thermostat Setting
Safety Thermostat Setting
High / Low Setting
Nominal Flue
Diameter
Boiler Water
Content
Boiler DRY Weight
less Burner Unit
Note.
Fuel rates and flue gas data relate to maximum output ratings.
Gas firing data relates to the use of NATURAL GAS ONLY.
Details for the use of LPG are available on request from Caradon
Ideal Ltd.
Natural gas consumption is calculated using a calorific value of
38.7MJ/m
3
(1038Btu/ft
3
) gross or 34.9MJ/m
15ºC and 1013.25mbar.
Oil rates relate to Gas Oil using a calorific value of 45.56 MJ/kg
gross or 42.69 MJ/kg nett.
2
GENERAL
GT 8
8
kW
390
Btu/hx10
3
1330
kW
300
3
Btu/hx10
1024
mbar
31.6
in w.g.
12.6
mbar
9.6
in w.g.
3.8
mbar
1.1
in w.g.
0.44
0
in w.g.
0
l/h
43.08
gal/h
9.48
3
m
/s
0.252
ft
3
/min
534
% / ºC
13 / 220
13 / 220
3
m
/h
44.78
3
ft
/h
1582
m
3
/s
0.279
3
ft
/min
591
% / ºC
9.5 / 220
9.5 / 220
in.
3
in.
3
in.
2
bar
6
ºC
30 - 90
ºC
110
ºC
30 - 90
m m
250
in.
10
l
366
gal
80.5
kg
1941
lb
4280
3
(935Btu/ft
3
) nett at
GT 9
GT 10
GT 11
9
10
450
540
1535
1842
2047
390
450
1330
1535
1842
49.3
75.9
19.7
30.3
14.9
23.0
6.0
9.2
1.5
2.0
0.6
0.8
0
0
0
0
49.76
59.51
66.42
10.95
13.09
14.61
0.290
0.348
0.387
614
737
13 / 220
13 / 220
51.74
61.88
69.06
1827
2185
2439
0.322
0.386
0.429
682
818
9.5 / 220
9.5 / 220
3
3
3
3
2
2
6
6
30 - 90
30 - 90
30 - 90
110
110
30 - 90
30 - 90
30 - 90
250
250
10
10
409
452
89.9
99.4
2027.5
2524
4470.5
5565
5494.5
HEALTH & SAFETY DOCUMENT NO. 635
The electricity at work regulations, 1989. The manufacturer's
notes must NOT be taken, in any way, as overriding statutory
obligations.
IMPORTANT. These appliances are CE certified for safety and
performance. It is, therefore, important that no external control
devices, e.g. flue dampers, economisers etc., are directly
connected to these appliances unless covered by these
Installation and Servicing Instructions or as otherwise
recommended by Caradon Ideal Limited in writing. If in doubt
please enquire.
Any direct connection of a control device not approved by
Caradon Ideal Limited could invalidate the certification and the
normal appliance warranty. It could also infringe the Gas Safety
Regulations and the above regulations.
GT 12
11
12
600
670
2286
540
600
2047
84.2
104.9
33.7
42.0
25.5
31.7
10.2
12.7
2.5
2.5
1.0
1.0
0
0
0
0
74.17
16.32
0.432
820
915
13 / 220
13 / 220
77.11
2723
0.479
909
1015
9.5 / 220
9.5 / 220
4
4
4
4
2
2
6
6
30 - 90
30 - 90
110
110
30 - 90
300
300
12
12
495
538
109
118.4
2492
2652.5
5849
Viceroy GT -
Installation & Servicing
GT 13
GT 14
13
14
720
780
2457
2661
670
720
2286
2457
127.9
161.4
51.2
64.6
38.7
48.8
15.5
19.5
2.5
3.5
1.0
1.4
0
0
0
0
79.71
86.35
17.54
19.00
0.465
0.503
985
1065
13 / 220
82.87
89.77
2927
3170
0.515
0.558
1091
1182
9.5 / 220
4
4
4
4
2
2
6
6
30 - 90
110
110
30-90
30-90
300
300
12
12
581
624
127.8
137.3
2881
3117
6353
6873

Advertisement

Table of Contents
loading

Table of Contents