B.4 MEMORY MAPPING
Bitmask
Element
33
Neutral Instantaneous Overcurrent 2
48
Neutral Time Overcurrent 1
49
Neutral Time Overcurrent 2
56
Neutral Directional Overcurrent 1
57
Neutral Directional Overcurrent 2
60
Negative Sequence Directional Overcurrent 1
B
61
Negative Sequence Directional Overcurrent 2
64
Ground Instantaneous Overcurrent 1
65
Ground Instantaneous Overcurrent 2
80
Ground Time Overcurrent 1
81
Ground Time Overcurrent 2
96
Negative Sequence Instantaneous Overcurrent 1
97
Negative Sequence Instantaneous Overcurrent 2
101
Opposite Phase Rotation
112
Negative Sequence Time Overcurrent 1
113
Negative Sequence Time Overcurrent 2
120
Negative Sequence Overvoltage 1
140
Auxiliary Undervoltage 1
144
Phase Undervoltage 1
145
Phase Undervoltage 2
146
Phase Undervoltage 3
148
Auxiliary Overvoltage 1
151
Phase Overvoltage 1
152
Phase Overvoltage 2
153
Phase Overvoltage 3
154
Compensated Overvoltage 1
156
Neutral Overvoltage 1
160
Phase Distance Zone 1
161
Phase Distance Zone 2
162
Phase Distance Zone 3
163
Phase Distance Zone 4
164
Phase Distance Zone 5
168
Line Pickup
172
Ground Distance Zone 1
173
Ground Distance Zone 2
174
Ground Distance Zone 3
175
Ground Distance Zone 4
176
Ground Distance Zone 5
180
Load Encroachment
190
Power Swing Detect
214
Sensitive Directional Power 1
215
Sensitive Directional Power 2
224
SRC1 VT Fuse Failure
225
SRC2 VT Fuse Failure
226
SRC3 VT Fuse Failure
227
SRC4 VT Fuse Failure
228
SRC5 VT Fuse Failure
229
SRC6 VT Fuse Failure
232
SRC1 50DD (Disturbance Detection)
233
SRC2 50DD (Disturbance Detection)
234
SRC3 50DD (Disturbance Detection)
235
SRC4 50DD (Disturbance Detection)
242
Open Pole Detector
B-88
Bitmask
280
281
282
283
288
289
290
291
292
293
294
295
311
312
313
336
337
344
345
346
347
352
353
354
355
356
357
360
362
363
365
366
368
370
371
372
374
388
389
390
391
392
393
394
395
396
400
401
402
403
404
405
406
D60 Line Distance Protection System
Element
Breaker Failure 1
Breaker Failure 2
Breaker Failure 3
Breaker Failure 4
Breaker Arcing Current 1
Breaker Arcing Current 2
Breaker Arcing Current 3
Breaker Arcing Current 4
Breaker Arcing Current 5
Breaker Arcing Current 6
Breaker 1 Flashover
Breaker 2 Flashover
Phasor measurement unit one-shot
Synchrocheck 1
Synchrocheck 2
Setting Group
Reset
Overfrequency 1
Overfrequency 2
Overfrequency 3
Overfrequency 4
Underfrequency 1
Underfrequency 2
Underfrequency 3
Underfrequency 4
Underfrequency 5
Underfrequency 6
Trip Output
Phase Selector
Open Pole Detector
Directional Comparison Unblocking Scheme
DUTT Pilot Scheme
PUTT Pilot Scheme
POTT Pilot Scheme
POTT1 Pilot Scheme
Hybrid POTT Pilot Scheme
Directional Comparison Blocking Pilot Scheme
Selector 1
Selector 2
Control pushbutton 1
Control pushbutton 2
Control pushbutton 3
Control pushbutton 4
Control pushbutton 5
Control pushbutton 6
Control pushbutton 7
FlexElement 1
FlexElement 2
FlexElement 3
FlexElement 4
FlexElement 5
FlexElement 6
FlexElemen 7
APPENDIX B
GE Multilin