B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 24 of 77)
ADDR
REGISTER NAME
Clock (Read/Write Setting)
419F
Synchronizing Source
Clock (Read/Write Command)
41A0
Real Time Clock Set Time
Clock (Read/Write Setting)
B
41A2
SR Date Format
41A4
SR Time Format
41A6
IRIG-B Signal Type
41A7
Clock Events Enable / Disable
41A8
Time Zone Offset from UTC
41A9
Daylight Savings Time (DST) Function
41AA
Daylight Savings Time (DST) Start Month
41AB
Daylight Savings Time (DST) Start Day
41AC
Daylight Savings Time (DST) Start Day Instance
41AD
Daylight Savings Time (DST) Start Hour
41AE
Daylight Savings Time (DST) Stop Month
41AF
Daylight Savings Time (DST) Stop Day
41B0
Daylight Savings Time (DST) Stop Day Instance
41B1
Daylight Savings Time (DST) Stop Hour
Fault Report Commands (Read/Write Command)
41B2
Fault Reports Clear Data Command
Oscillography (Read/Write Setting)
41C0
Oscillography Number of Records
41C1
Oscillography Trigger Mode
41C2
Oscillography Trigger Position
41C3
Oscillography Trigger Source
41C5
Oscillography AC Input Waveforms
41D0
Oscillography Analog Channel n (16 items)
4200
Oscillography Digital Channel n (63 items)
Trip and Alarm LEDs (Read/Write Setting)
42B0
Trip LED Input FlexLogic Operand
42B2
Alarm LED Input FlexLogic Operand
User Programmable LEDs (Read/Write Setting) (48 Modules)
42C0
FlexLogic Operand to Activate LED
42C2
User LED type (latched or self-resetting)
42C3
...Repeated for User-Programmable LED 2
42C6
...Repeated for User-Programmable LED 3
42C9
...Repeated for User-Programmable LED 4
42CC
...Repeated for User-Programmable LED 5
42CF
...Repeated for User-Programmable LED 6
42D2
...Repeated for User-Programmable LED 7
42D5
...Repeated for User-Programmable LED 8
42D8
...Repeated for User-Programmable LED 9
42DB
...Repeated for User-Programmable LED 10
42DE
...Repeated for User-Programmable LED 11
42E1
...Repeated for User-Programmable LED 12
42E4
...Repeated for User-Programmable LED 13
42E7
...Repeated for User-Programmable LED 14
42EA
...Repeated for User-Programmable LED 15
42ED
...Repeated for User-Programmable LED 16
42F0
...Repeated for User-Programmable LED 17
42F3
...Repeated for User-Programmable LED 18
42F6
...Repeated for User-Programmable LED 19
B-32
RANGE
0 to 3
0 to 235959
0 to 4294967295
0 to 4294967295
0 to 2
0 to 1
–24 to 24
0 to 1
0 to 11
0 to 6
0 to 4
0 to 23
0 to 11
0 to 6
0 to 4
0 to 23
0 to 1
3 to 64
0 to 1
0 to 100
0 to 4294967295
0 to 4
0 to 65535
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 1
D60 Line Distance Protection System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F623
---
1
F050
---
1
F051
---
1
F052
---
1
F114
---
1
F102
hours
0.5
F002
---
1
F102
---
1
F237
---
1
F238
---
1
F239
---
1
F001
---
1
F237
---
1
F238
---
1
F239
---
1
F001
---
1
F126
---
1
F001
---
1
F118
%
1
F001
---
1
F300
---
1
F183
2 (16 samples/
---
1
F600
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F127
1 (Self-Reset)
DEFAULT
0 (none)
0
0
0
0 (None)
0 (Disabled)
0
0 (Disabled)
0 (January)
0 (Sunday)
0 (First)
2
0 (January)
0 (Sunday)
0 (First)
2
0 (No)
15
0 (Auto.
Overwrite)
50
0
cycle)
0
0
0
0
0