GE D60 Instruction Manual page 684

Ur series line distance protection system
Hide thumbs Also See for D60:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 54 of 77)
ADDR
REGISTER NAME
A867
Block 1 1P Rx Coord Pickup Delay
A868
Block 1 1P Transient Block Pickup Delay
A869
Block 1 1P Transient Block Reset Delay
A86A
Blocking 1 Scheme 1P Seal in Delay
A86B
Blocking 1 Scheme 1P Dir Fwd 1
B
A86D
Blocking 1 Scheme 1P Dir Fwd 2
A86F
Blocking 1 Scheme 1P Dir Fwd 3
A871
Blocking 1 Scheme 1P Dir Rev 1
A873
Blocking 1 Scheme 1P Dir Rev 2
A875
Blocking 1 Scheme 1P Dir Rev 3
A877
Blocking 1 Scheme 1P Force Tx Stop 1
A879
Blocking 1 Scheme 1P Force Tx Stop 2
A87B
Blocking 1 Scheme 1P Comm Bits
A87C
Blocking 1 Scheme 1P Rx1
A87E
Blocking 1 Scheme 1P Rx2
A880
Blocking 1 Scheme 1P Rx3
A882
Blocking 1 Scheme 1P Rx4
A884
Blocking 1 1P Target
A885
Blocking 1 1P Event
Frequency Rate of Change (Read/Write Setting) (4 Modules)
A900
Frequency Rate of Change 1 Function
A901
Frequency Rate of Change 1 OC Supervision
A902
Frequency Rate of Change 1 Min
A903
Frequency Rate of Change 1 Max
A904
Frequency Rate of Change 1 Pickup Delay
A905
Frequency Rate of Change 1 Reset Delay
A906
Frequency Rate of Change 1 Block
A908
Frequency Rate of Change 1 Target
A909
Frequency Rate of Change 1 Events
A90A
Frequency Rate of Change 1 Source
A90B
Frequency Rate of Change 1 Trend
A90C
Frequency Rate of Change 1 Pickup
A90D
Frequency Rate of Change 1 OV Supervision
A90E
Frequency Rate of Change 1 Reserved (3 items)
A911
...Repeated for Frequency Rate of Change 2
A922
...Repeated for Frequency Rate of Change 3
A933
...Repeated for Frequency Rate of Change 4
IEC 61850 Received Analog Settings (Read/Write) (32 Modules)
AA00
IEC 61850 GOOSE analog 1 default value
AA02
IEC 61850 GOOSE analog input 1 mode
AA03
IEC 61850 GOOSE analog input 1 units
AA05
IEC 61850 GOOSE analog input 1 per-unit base
AA07
...Repeated for IEC 61850 GOOSE analog input 2
AA0E
...Repeated for IEC 61850 GOOSE analog input 3
AA15
...Repeated for IEC 61850 GOOSE analog input 4
AA1C
...Repeated for IEC 61850 GOOSE analog input 5
AA23
...Repeated for IEC 61850 GOOSE analog input 6
AA2A
...Repeated for IEC 61850 GOOSE analog input 7
AA31
...Repeated for IEC 61850 GOOSE analog input 8
AA38
...Repeated for IEC 61850 GOOSE analog input 9
AA3F
...Repeated for IEC 61850 GOOSE analog input 10
AA46
...Repeated for IEC 61850 GOOSE analog input 11
AA4D
...Repeated for IEC 61850 GOOSE analog input 12
AA54
...Repeated for IEC 61850 GOOSE analog input 13
B-62
RANGE
0 to 65.535
0 to 65.535
0 to 65.535
0 to 65.535
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 2
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 2
0 to 1
0 to 1
0 to 30
20 to 80
20 to 80
0 to 65.535
0 to 65.535
0 to 4294967295
0 to 2
0 to 1
0 to 5
0 to 2
0.1 to 15
0.1 to 3
0 to 1
–1000000 to 1000000
0 to 1
---
0 to 999999999.999
D60 Line Distance Protection System
APPENDIX B
UNITS
STEP
FORMAT
s
0.001
F001
s
0.001
F001
s
0.001
F001
s
0.001
F001
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F198
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F109
---
1
F102
---
1
F102
pu
0.001
F001
Hz
0.01
F001
Hz
0.01
F001
s
0.001
F001
s
0.001
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F167
---
1
F224
Hz/s
0.01
F001
pu
0.001
F001
---
1
F001
---
0.001
F060
---
1
F491
0 (Default Value)
---
---
F207
---
0.001
F060
DEFAULT
10
30
90
0
0
0
0
0
0
0
0
0
0 (1)
0
0
0
0
0 (Self-reset)
0 (Disabled)
0 (Disabled)
200
4500
6500
0
0
0
0 (Self-reset)
0 (Disabled)
0 (SRC 1)
0 (Increasing)
50
700
0
1000
(none)
1
GE Multilin