GE D60 Instruction Manual page 657

Ur series line distance protection system
Hide thumbs Also See for D60:
Table of Contents

Advertisement

APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 27 of 77)
ADDR
REGISTER NAME
47DF
Breaker 1 External Alarm
47E1
Breaker 1 Alarm Delay
47E3
Breaker 1 Pushbutton Control
47E4
Breaker 1 Manual Close Recall Time
47E6
Breaker 1 Out of Service
47E8
Breaker 1 Block Open
47EA
Breaker 1 Block Close
47EC
Breaker 1 Phase A / Three-pole Opened
47EE
Breaker 1 Phase B Opened
47F0
Breaker 1 Phase C Opened
47F2
Breaker 1 Operate Time
47F3
Breaker 1 Events
47F4
Reserved
47F5
...Repeated for breaker 2
481A
...Repeated for breaker 3
483F
...Repeated for breaker 4
Compensated Overvoltage (Read/Write Grouped Setting)
48F0
Compensated OV Function
48F1
Compensated OV Sourced
48F2
Compensated OV Zc Mag
48F3
Compensated OV Zc Ang
48F4
Compensated OV I_1max
48F5
Compensated OV STG1 PKP
48F6
Compensated OV STG1 Delay
48F7
Compensated OV STG2 PKP
48F8
Compensated OV STG2 Delay
48F9
Compensated OV SGT3 PKP
48FA
Compensated OV STG3 Delay
48FB
Compensated OV Block
48FD
Compensated OV Target
48FE
Compensated OV Events
FlexCurve A (Read/Write Setting)
4910
FlexCurve A (120 items)
FlexCurve B (Read/Write Setting)
4988
FlexCurve B (120 items)
Modbus User Map (Read/Write Setting)
4A00
Modbus Address Settings for User Map (256 items)
User Displays Settings (Read/Write Setting) (16 Modules)
4C00
User-Definable Display 1 Top Line Text
4C0A
User-Definable Display 1 Bottom Line Text
4C14
Modbus Addresses of Display 1 Items (5 items)
4C19
Reserved (7 items)
4C20
...Repeated for User-Definable Display 2
4C40
...Repeated for User-Definable Display 3
4C60
...Repeated for User-Definable Display 4
4C80
...Repeated for User-Definable Display 5
4CA0
...Repeated for User-Definable Display 6
4CC0
...Repeated for User-Definable Display 7
4CE0
...Repeated for User-Definable Display 8
4D00
...Repeated for User-Definable Display 9
4D20
...Repeated for User-Definable Display 10
4D40
...Repeated for User-Definable Display 11
4D60
...Repeated for User-Definable Display 12
4D80
...Repeated for User-Definable Display 13
GE Multilin
RANGE
0 to 4294967295
0 to 65.535
0 to 1
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 65.535
0 to 1
0 to 65535
0 to 1
0 to 5
0 to 500
30 to 90
0.01 to 1
0.25 to 3
0 to 600
0.25 to 3
0 to 600
0.25 to 3
0 to 600
0 to 4294967295
0 to 2
0 to 1
0 to 655535
0 to 655535
0 to 65535
---
---
0 to 65535
---
D60 Line Distance Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F300
s
0.001
F003
---
1
F102
s
0.001
F003
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
s
0.001
F001
---
1
F102
s
1
F001
---
1
F102
---
1
F167
ohm
0.01
F001
degree
1
F001
pu
0.01
F001
pu
0.001
F001
sec
0.01
F001
pu
0.001
F001
sec
0.01
F001
pu
0.001
F001
sec
0.01
F001
---
1
F300
---
1
F109
---
1
F102
ms
1
F011
ms
1
F011
---
1
F001
---
---
F202
---
---
F202
---
1
F001
---
---
F001
DEFAULT
0
0
0 (Disabled)
0
0
B
0
0
0
0
0
70
0 (Disabled)
0
0 (Disabled)
0 (SRC 1)
200
90
20
1300
100
1300
100
1300
100
0
0 (Self-reset)
0 (Disabled)
0
0
0
" "
""
0
0
B-35