GE D60 Instruction Manual page 645

Ur series line distance protection system
Hide thumbs Also See for D60:
Table of Contents

Advertisement

APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 15 of 77)
ADDR
REGISTER NAME
Security (Read Only)
32E9
Reserved for Password Settings of Future Roles (63 items)
3328
Security Status Indicator
Security (Read/Write Setting)
3329
Session Lockout
332A
Session Lockout Period
332B
Load Factory Defaults
332C
Syslog Server IP Address
332E
Syslog Server Port Number
Security Supervisory (Read/Write Setting)
3331
Device Authentication Enable
3332
Supervisor Role Enable
3333
Lock Relay
3334
Factory Service Mode Enable
3335
Failed Authentication Alarm Enable
3336
Firmware Lock Alarm
3337
Settings Lock Alarm
3338
Bypass Access
3339
Encryption
333A
Serial Inactivity Timeout
Security Command (Read/Write Command)
3350
Operator Logoff
3351
Engineer Logoff
3352
Administrator Logoff
3353
Clear Security Data
Security Reserved Modbus Registers (Read/Write)
3360
Address 0x3360 reserved for serial login (20 items)
3374
Address 0x3374 reserved for serial logout
Security Reserved Modbus Registers (Read Only)
3375
Address 0x3374 reserved for serial logout
Event Recorder Actual Values (Read Only)
3400
Events Since Last Clear
3402
Number of Available Events
3404
Event Recorder Last Cleared Date
Event Recorder Commands (Read/Write)
3406
Event Recorder Clear Command
DCmA Input Values (Read Only) (24 Modules)
34C0
DCmA Inputs 1 Value
34C2
DCmA Inputs 2 Value
34C4
DCmA Inputs 3 Value
34C6
DCmA Inputs 4 Value
34C8
DCmA Inputs 5 Value
34CA
DCmA Inputs 6 Value
34CC
DCmA Inputs 7 Value
34CE
DCmA Inputs 8 Value
34D0
DCmA Inputs 9 Value
34D2
DCmA Inputs 10 Value
34D4
DCmA Inputs 11 Value
34D6
DCmA Inputs 12 Value
34D8
DCmA Inputs 13 Value
34DA
DCmA Inputs 14 Value
34DC
DCmA Inputs 15 Value
34DE
DCmA Inputs 16 Value
34E0
DCmA Inputs 17 Value
GE Multilin
RANGE
0 to 65535
0 to 65535
0 to 99
0 to 9999
0 to 1
0 to 4294967295
1 to 65535
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
1 to 9999
0 to 1
0 to 1
0 to 1
0 to 1
0 to 9999
0 to 9999
0 to 5
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 1
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
D60 Line Distance Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F001
---
1
F618
---
1
F001
min
1
F001
---
1
F126
---
1
F003
---
1
F001
---
1
F126
---
1
F102
---
1
F102
---
1
F102
---
1
F102
---
1
F102
---
1
F102
---
1
F628
---
1
F102
---
1
F001
---
1
F126
---
1
F126
---
1
F126
---
1
F126
---
1
F001
---
1
F001
---
1
F617
---
1
F003
---
1
F003
---
1
F050
---
1
F126
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
DEFAULT
0
0
3
B
3
0 (No)
0
514
1 (Yes)
0 (Disabled)
0 (Disabled)
0 (Disabled)
1 (Enabled)
1 (Enabled)
1 (Enabled)
0 (Disabled)
1 (Enabled)
1
0 (No)
0 (No)
0 (No)
0 (No)
3
3
3 (Engineer)
0
0
0
0 (No)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
B-23

Advertisement

Table of Contents
loading

Table of Contents