Drive Cliq Interfaces X100 - X105 - Siemens SINUMERIK 840D sl Manual

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Interfaces

6.2 DRIVE CLiQ Interfaces X100 - X105

6.2
DRIVE CLiQ Interfaces X100 - X105
Properties
● Automatic detection of components
● 24 V / 450 mA per DRIVE-CLiQ interface is provided for the connection of encoders and
Features
Table 6-2
Feature
Plug-connector type
Cable type
Cable type
Maximum cable length
DRIVE-CliQ pin assignment
Table 6-3
PIN
1
2
3
4
5
6
7
8
A
B
Signal type: I = Input; O = Output; VO = Voltage Output
44
measuring systems
X100 - X103 or X100 – X105
DRIVE-CLiQ interface (X100 - X103 or X100 – X105)
Signal name
TXP
TXN
RXP
RXN
+ (24 V)
M (0 V)
Version
DRIVE-CLiQ plug
DRIVE-CLiQ standard (inside the control cabinet)
MOTION CONNECT (outside the control cabinet)
100 m
Signal type
Meaning
O
Transmit data +
O
Transmit data -
I
Receive data +
Reserved, do not use!
Reserved, do not use
I
Receive data -
Reserved, do not use
Reserved, do not use
VO
Voltage supply for DRIVE-CLiQ, 450 mA maximum
VO
Ground to 24 V
Manual, 07/2007, 6FC5397-0AP10-2BA0