Interfaces
6.6 Digital inputs/outputs X122 and X132
6.6.3

Technical data

Digital inputs on X122/X132
Table 6-15
Parameter
Voltage
Typical power consumption
Galvanic isolation
Signal level (including ripple)
Signal propagation delays
Digital inputs/outputs on X122/X132
Table 6-16
Parameter
Voltage
Typical power consumption
Signal level (including ripple)
Pins 8, 10 and 11 are "rapid inputs"
Signal propagation delays of inputs/"rapid inputs"
Voltage
Maximum load current per output
Note
An open input is interpreted as "low".
Only "rapid inputs" can be used as inputs for BEROs and probes.
Terminals M1 or M2 must be connected for the digital inputs to work. This can be done as
follows:
Connect the coupled-motion reference ground of the digital inputs, or provide a jumper to
terminal M. (Notice! This removes the galvanic isolation for these digital inputs.)
56
Technical data of digital inputs X122/X132
Technical data of the digital inputs/outputs of X122/X132
Values
-3 V to 30 V
10 mA at 24 V DC
Reference potential is terminal M1 or M2
High signal level: 15 V to 30 V
Low signal level: -3 V to 5 V
L → H: 50 μs
H → L: 100 μs
Values
As an input
-3 V to 30 V
10 mA at 24 V DC
High signal level: 15 V to 30 V
Low signal level: -3 V to 5 V
L → H: 50 μs/5 μs
H → L: 100 μs/50 μs
As an output
24 V DC
500 mA
Manual, 07/2007, 6FC5397-0AP10-2BA0