5.3

LED displays

Table 5-1
Meaning of LED states
Name
Function
RDY
Ready
RUN
PLC RUN
STOP
PLC STOP
SU/PF
PLC FORCE
SF
PLC SF
DP1
BUS1 F
DP2
BUS2 F
OPT *)
BUS3 F
*) The "OPT" LED is only significant for "PN NCUs".
NOTICE
If all the LEDs are flashing, the PLC must be reset via the mode selector (move switch to
position "3" to reboot).
Note
While the Control Unit is starting up, all LEDs are illuminated yellow for a brief time. You can
carry out a detailed diagnosis using a PG/PC and the HMI software.
Additional references
You can find a detailed description of LED states in Chapter 10 of the:
S7-300 CPU 31xC and CPU 31x Operating Instructions: Configuring
NCU
Manual, 07/2007, 6FC5397-0AP10-2BA0
Status
Meaning
Red
There is at least one fault (e.g. RESET, watchdog monitoring etc. ) or
the Control Unit is booting up.
Flashing red/yellow
Error accessing CompactFlash Card
(0.5 Hz)
Yellow
Accessing CompactFlash Card
Green
PLC ready to operate
Yellow
PLC stopped
Red
FORCE activated
Red
PLC group error
Red
PROFIBUS-DP1 group error
Red
PROFIBUS-DP2 group error
Off
The PROFINET system runs correctly; data exchange to all
configured IO devices runs.
Red
Flashing red
(2 Hz)
Bus fault (no physical connection)
Incorrect transmission rate
Failure of a connected I/O device.
Incorrect or no configuration.