Application; Power Supply X124 - Siemens SINUMERIK 840D sl Manual

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

6.6.4

Application

Connecting sensors and actuators
Digital inputs and outputs can be used to connect various sensors and actuators to the two
12-pin connectors (X122 and X132) on the front panel.
The following types of digital I/O are used:
● Digital inputs
● Bidirectional digital inputs/outputs
The assignment of I/Os to functions can be parameterized freely by the user. Special
functions, such as probe input and cam output, can also be assigned to the I/Os.
The enables for the drive units and/or motors (Line Module, Motor Module) connected to the
control unit can be switched using the digital inputs.
6.7

Power supply X124

Features of the interface
Table 6-17
Features
Connector type
Connection possibility
Current carrying capacity
Maximum cable length
Interface assignments
Table 6-18
Pin
1
2
3
4
Signal type: VI = Voltage input (power supply) VO = Voltage output (power supply)
NCU
Manual, 07/2007, 6FC5397-0AP10-2BA0
Interface X124
Power supply X124
Signal name
P24
P24
M
M
Type
Combicon
up to 2.5 mm
2
10 A, maximum
10 m
Signal type
VI
VI
VO
VO
Interfaces
6.7 Power supply X124
Meaning
Power supply 24 V
Ground