Use flexible cables with a cross section of 0.25 to 2.5 mm
the power supply.
If you only use one wire per connection, a ferrule is not required.
You can use ferrules without an insulating collar in accordance with DIN 46228, Form A long
version.
9.5

DRIVE CLiQ components

9.5.1

DRIVE-CLiQ wiring

The components of the SINAMICS S120 drive family and the control unit are interconnected
using DRIVE-CLiQ. When connecting the components, please follow the rules in the
documentation below without exception:
The "Connecting components" section of the "Machine Configuration Guidelines" System
Manual
Cable specification
Table 9-4
Feature
Connector type
Cable type
Max. cable length
NCU
Manual, 03/2010, 6FC5397-0AP10-3BA0
Cable specifications for X100 - X103 or X100 – X105
Specification
RJ45 socket
DRIVE-CLiQ standard (inside the control cabinet)
MOTION CONNECT (outside the control cabinet)
70 m
9.5 DRIVE CLiQ components
(or AWG 23 to AWG 13) for wiring
2
Connecting
67