Operating And Display Elements - Siemens SINUMERIK 840D sl Manual

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Spare Parts/Accessories
11.2 NX10/15
11.2.2

Operating and display elements

LED displays
Table 11-1
Description of LEDs on the NX10/15
LED
Color
Off
RDY,
Green
READY
H1
Red
Orange
Off
DP1,
Green
CU_LINK
H2
Red
RESET button
The RESET button is on the front of the module under the cover.
NOTICE
When the pushbutton is actuated, the locally connected drive systems are brought to a
standstill with no feedback to the control. In other words, the drive and control run
asynchronously once the drive has successfully booted up.
92
Status
Description
Electronic power supply outside permissible tolerance range
Steady-light signal
NX10/15 is ready for operation
Blinklight 2 Hz
Writing to CompactFlash Card
Continuous light
At least one fault is pending (e.g., RESET, watchdog monitoring,
basic system fault).
NX10/15 is booting up.
Blinklight 0.5 Hz
Boot fault (e.g., firmware cannot be loaded into the RAM)
Continuous light
Firmware loading into RAM
0.5 Hz flashing light
Unable to load firmware into RAM
2 Hz flashing light
Firmware CRC fault
Electronic power supply outside the permissible tolerance range,
NX10/15 is not ready for operation.
Continuous light
CU_LINK is ready for communication and cyclic communication is
running
0.5 Hz flashing light
CU_LINK is ready for communication and no cyclic communication is
running
Continuous light
At least one CU_LINK fault is present.
CU_LINK not ready for operation (e.g., after POWER ON)
Manual, 03/2010, 6FC5397-0AP10-3BA0
NCU

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents