18 CONFIGURATION EXAMPLES

Here are listed few simple configuration examples.

18.1 ALARM CONFIGURATION

To send alarm on input 1 please set these parameters:
;LN1=123;TN1=040211411;TN2M=041211511;TN3=051334556;
With these configuration alarm notification will be send to TN1 (voice and SMS), TN2 (only SMS)
and TN3 (only voice).

18.2 CID EVENT REPORTING

This example represents how to enable CID function for ZEUS4-VD event reporting. The data will
be sending to 1 CMS.
;CID=1;CIN=15;COUT=12;TN11=042340880;