Set-Up Parameters - MARS COMMERCE ZEUS4-VD Installation Manual

Voice & sms gsm alarm
Hide thumbs Also See for ZEUS4-VD:
Table of Contents

Advertisement

ZEUS4-VD

11.6 SET-UP PARAMETERS

Different parameters are used to support versatile functionality of ZEUS4-VD.
11.6.1
CRE parameter
Repetition of alarm calling sequences. With the number from 1 to 99 we define how often the
sequence is repeated in case the number is busy or not answered.
11.6.2
UDC parameter
Parameter is used to synchronies ZEUS4-VD clock to GSM network clock. User must enter here
the number of the ZEUS4-VD SIM card (Telephone number of ZEUS4-VD device).
11.6.3
HTN parameter
Hidden telephone number. This function ("0" value) is used in order to conceal the telephone
number of the ZEUS4-VD device. Value "1" means that the number is displayed.
11.6.4
TST parameter
A test SMS is sent periodically. ZEUS4-VD can send the test message in the interval ranging from
1 hour to 240 hours.
Example:
To send test SMS TST value is set to 12, the numbers linked to "LN7" receive a test
message every 12 hours.
11.6.5
TSTT parameter
TSTT parameter is used to define reference point for sending test message. If this parameter is set
than after restart of the ZEUS4-VD first test SMS will be send out at time defined with TSTT
parameter.
Parameter value is defined in hours.
Example:
To receive first test SMS at 20.00h TSTT value must be set to 20
NOTE
By setting TSTT=0 this function is disabled