ZEUS4-VD
11.2.7
OS parameters
ZEUS4-VD device has 4 open collector outputs and each of them can be programmed in a different
way: as a bi-stable or mono-stable (pulse) output. The programming time is in seconds and can
be set from 2-9999 seconds.
Typical connection for the output:
OSX = 0 – Selected output is disabled
OSX = 1 – Selected output is in bi-stable toggle mode
OSX = 2 – Selected output is in mono-stable pulse mode (pulse time is set to 2 seconds)
Where X is one of the output numbers from 1 to 4.
Table of parameters:
Name
OS1
OS2
OS3
OS4
Example:
Direct programming on the SIM card
Name
OS1
OS4
Remote programming by SMS
;OS1=1;OS4=14;
If you would like to receive SMS message with the Output status write "+" before SMS
command:
Remote programming by SMS
;+OS1=1;OS4=14;
st
Control for the 1
output
nd
Control for the 2
rd
Control for the 3
output
th
Control for the 4
output
Table 15: OS parameters
ZEUS4-VD PROGRAMMING TABLE
SIM CARD PHONE BOOK
Number
st
Output – Bistable toggle mode
1
1
th
Output – Monostable pulse mode (14 sec. pulse)
14
4
Table 16: OS parameters example
Comment
output
Description
18