Table 19: It, Ar And Ib Parameters; Table 20: It, Ar And Ib Parameters Example - MARS COMMERCE ZEUS4-VD Installation Manual

Voice & sms gsm alarm
Hide thumbs Also See for ZEUS4-VD:
Table of Contents

Advertisement

ZEUS4-VD
AR – parameter defines the maximum number of alarms trigged in IT time
IB – IB parameter defines how long (in seconds) sending of alarm events is blocked when
automatic input block system in enabled.
Table of parameters:
Name
IT1
IT2
IT3
IT4
AR1
AR2
AR3
AR4
IB1
IB2
IB3
IB4
Example:
Input 1 will be blocked for 10 minutes if 10 alarm events are triggered within 125 seconds
Input 2 will be blocked for 1 hour if 5 alarm events are triggered within 12 minutes.
 Direct programming on the SIM card
Name
IT1
AR1
IB1
IT2
AR2
IB2
 Remote programming by SMS
;IT1=125;AR1=10;IB1=600; IT2=720;AR2=5;IB2=3600;
Arm/disarm events on ZEUS4-VD resets bypass function.
NOTE
st
Time interval 1
input
nd
Time interval 2
input
rd
Time interval 3
input
th
Time interval 4
input
Maximum allowed number of events on 1
Maximum allowed number of events on 2
Maximum allowed number of events on 3
Maximum allowed number of events on 4
System block time on 1
System block time on 2
System block time on 3
System block time on 4

Table 19: IT, AR and IB parameters

ZEUS4-VD PROGRAMMING TABLE
SIM CARD PHONE BOOK
Number
125
Time interval on input 1
10
Max number of alarm events on input 1
600
System block time on input 1
720
Time interval on input 2
5
Max number of alarm events on input 2
3600
System block time on input 2

Table 20: IT, AR and IB parameters example

Comment
st
input
nd
input
rd
input
th
input
st
input
nd
input
rd
input
th
input
Description
20
INSTALLATION MANUAL

Advertisement

Table of Contents
loading

Table of Contents