AR – parameter defines the maximum number of alarms trigged in IT time
IB – IB parameter defines how long (in seconds) sending of alarm events is blocked when
automatic input block system in enabled.
Table of parameters:
Name
IT1
IT2
IT3
IT4
AR1
AR2
AR3
AR4
IB1
IB2
IB3
IB4
Example:
Input 1 will be blocked for 10 minutes if 10 alarm events are triggered within 125 seconds
Input 2 will be blocked for 1 hour if 5 alarm events are triggered within 12 minutes.
Direct programming on the SIM card
Name
IT1
AR1
IB1
IT2
AR2
IB2
Remote programming by SMS
;IT1=125;AR1=10;IB1=600; IT2=720;AR2=5;IB2=3600;
Arm/disarm events on ZEUS4-VD resets bypass function.
NOTE
st
Time interval 1
input
nd
Time interval 2
input
rd
Time interval 3
input
th
Time interval 4
input
Maximum allowed number of events on 1
Maximum allowed number of events on 2
Maximum allowed number of events on 3
Maximum allowed number of events on 4
System block time on 1
System block time on 2
System block time on 3
System block time on 4
Table 19: IT, AR and IB parameters
ZEUS4-VD PROGRAMMING TABLE
SIM CARD PHONE BOOK
Number
125
Time interval on input 1
10
Max number of alarm events on input 1
600
System block time on input 1
720
Time interval on input 2
5
Max number of alarm events on input 2
3600
System block time on input 2
Table 20: IT, AR and IB parameters example