DESCRIPTION OF TERMINAL BLOCKS

+BATT/Ground – Battery backup connector. In the original metal box it is possible to place a
1,2Ah/12V battery. Red fasten connector is for positive and black fasten connector is for negative
voltage battery supply.
+13,8V/Ground – Power Supply connector - On the left side is positive voltage (+ 12 VDC to
+15VDC) and the right site is GND voltage.
Input 1 – Alarm input 1 - It can be N.O. (normal open) to GND or +12V DC, N.C. (normal close)
to GND or +12V DC.
Input 2 – Alarm input 2 - It can be N.O. (normal open) to GND or +12V DC, N.C. (normal close)
to GND or +12V DC.
Input 3 – Alarm input 3 - It can be N.O. (normal open) to GND or +12V DC, N.C. (normal close)
to GND or +12V DC.
Input 4 – Alarm input 4 - It can be N.O. (normal open) to GND or +12V DC, N.C. (normal close)
to GND or +12V DC.
ON/OFF – System arm/disarm - It can be N.O. (normal open) to GND or +12V DC, N.C. (normal
close) to GND or +12V DC.
NOTE
For the arm/disarm function the ION parameter must be 4, 5 or 6!
Output 1 – First diagnostic, remote control or alarm output. It is Open Collector output with
maximum loading current of 500mA.
Output 2 – Second diagnostic, remote control or alarm output. It is Open Collector output with
maximum loading current of 500mA.
Output 3 – Third diagnostic, remote control or alarm output. It is Open Collector output with
maximum loading current of 500mA.
Output 4 – Fourth diagnostic, remote control or alarm output. It is Open Collector output with
maximum loading current of 500mA.