Event Log Parameters; Table 33: Log Parameters; Table 34: Log Parameters Example - MARS COMMERCE ZEUS4-VD Installation Manual

Voice & sms gsm alarm
Hide thumbs Also See for ZEUS4-VD:
Table of Contents

Advertisement

ZEUS4-VD

11.8 EVENT LOG PARAMETERS

ZEUS4-VD has a small set of parameters to manage log memory.
11.8.1
LOGN parameter
LOGN parameter is used to define the number of log events that will be send out in case of PLOG
command
11.8.2
LOGI parameter
LOGN parameter is used to enable and define ZEUS4-VD log storage.
 LOGI=0
 LOGI=1
 LOGI=2
11.8.3
ALC parameter
ALC parameter defines an action in case when the LOG memory is FULL
 ALC=0
Automatically delete buffer when memory is FULL
 ALC=1
Memory buffer must be deleted manually when it is FULL
Table of parameters:
Name
LOGI
LOGN
ALC
Example:
 Direct programming on the SIM card
Name
LOGI
LOGN
ALC
 Remote programming by SMS
;LOGI=1;LOGN=10;ALC=1;
Logging is OFF
Logging in internal memory
Logging to USB interface
Log storage
Number of log events for print
Control for memory handling in case memory storage is full

Table 33: LOG parameters

ZEUS4-VD PROGRAMMING TABLE
SIM CARD PHONE BOOK
Number
1
10
1

Table 34: LOG parameters example

Comment
Description
Use internal ZEUS4-VD storage
Send 10 events in case of PLOG request
Automatically delete memory buffer when is full
34
INSTALLATION MANUAL