7.3 Adjustment of Lenses

M
AL
Adjustment
of flange focus for
fixed focus lenses
Adjustment
of flange focus for
variable focus lenses
C mount lens
CS mount lens
This adjustment (distance between lens casing and sensor surface)
is required if a sharpdefinition cannot be obtained with the lens
focussing, or in order to adjust the ∞ position.
To obtain a sharp definition, point the camera at an object which
is at least 000 times further away from the front of the lens than
the focal length. (If the focal length is 7.5mm, the object must be at
least 5m distant from the camera).
Open the aperture fully and set the focus to ∞ (infinite).
If the lens has automatic exposure control, select a dark object,
or better use an ND filter (64-x) to ensure that the aperture is fully
open.
Undo set screw 1 on flange focus adj. lever. Turn the lever in left or
right direction until the definition is sharp.
When finished, retighten screw 1.
To obtain a sharp definition, point the camera at an object which is
at least 5 times the minimum lens distance (MOD) of the lens. (If
this is m, the object must be at least 5m distant from the camera).
Open the iris fully and set the lens to the maximum tele position
and focus with the focus ring.
If the lens has automatic iris control, select a dark object (or use an
ND filter, 64-x) to ensure that the iris is fully open.