RF660R reader
5.2
5.2
5.3
Installation /Mounting
5.3.1
Mounting/Installation
Mounting/installing the device
The positions of the fixing holes for the device are shown in the "Dimension drawing"
section.
Examples of mounting types
Material
Concrete
Plasterboard
(min. 13 mm thick)
Metal
(min. 2 mm thick)
Warning
Ensure that the wall or ceiling can hold four times the total weight of the device.
5.4
Configuration/integration
5.4.1
Configuration
Three communication interfaces are available for integrating the device into system
environments/networks:
5-10
Hole diameter
8 mm diameter
60 mm depth
14 mm diameter
5 mm diameter
System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618,
Fixing
Rawlplug: 8 mm diameter, 50 mm length
Screws: 4 mm diameter, 50 mm length
Tilting rawlplug: 4 mm diameter, 50 mm length
M4 metal screws: 4 mm diameter,
15 mm length