Reliance electric GV3000/SE Hardware Reference, Installation, And Troubleshooting Manual page 76

Bookshelf drive
Hide thumbs Also See for GV3000/SE:
Table of Contents

Advertisement

10-6
Meter
IGBT
Connection
No.
(+)
(-)
V6
47*
W(T3)
V5
47*
V(T2)
V4
47*
U(T1)
V3
W(T3)
45*
V2
V(T2)
45*
V1
U(T1)
45*
*If the optional terminals 45 and 47 are not fitted (e.g., on drives with built-in chopper option), remove
cover and connect the meter to the measuring points according to the procedure in section 10.3.
Component is OK if
resistance (R) is:
0.3 < R < 8K ohm
GV3000/SE AC Bookshelf Drive Hardware Reference, Version 6.06
Component is defective if:
Continuity (short circuit) or
open when the meter is
connected with reversed
polarity

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Reliance electric GV3000/SE