Item
Fastening Components
Regulated Torque
Value
Required Tools
2) Install a ground cable from the MGB to the ground terminal of the Outdoor AP.
3) After assembling a pressure terminal with a heat shrink tube, secure it firmly into the
ground terminal of the system using the M6 SEMS.
Samsung Electronics America
MGB
Outdoor AP
M6 SEMS
Cable Cutter, Wire Stripper, Crimper, Heating Gun, Torque Driver (+),
Torque Wrench, and Nipper

Figure 34. Connecting a Ground Cable to the Outdoor AP (1)

Fastening components, such as the pressure terminal or cables, must meet the
UL or equivalent standards requirements.
Ex) Manufacturer: Panduit
Outdoor AP: 4 mm
For information on how to assemble the pressure terminal and the heat shrink
tube, see ANNEX C.
Description
Check the MGB standards for the field and have the
fasteners ready.
M6 × 12L SEMS/2 EA (tightened to the system)
33.28~49.92 kgf·cm
Ground Cable
2
Pressure Terminal (LCD10-14A-L)