Troubleshooting Volume Retention

If an error occurs with Volume Retention, the
Error Detail dialog box displays error locations and error messages.
170 Troubleshooting
Error Contents
The operation to increase capacity cannot be
performed on the specified THP V-VOL.
The operation was rejected because of lack of
cache management devices due to increased
capacity.
Because the specified volume was not a THP
V-VOL, the operation was rejected.
Because the specified capacities are invalid or
exceeded the value immediately below LDEV
Capacity in the Expand Virtual Volumes
window, the operation was rejected.
Because the specified volume operation was not
finished, the operation was rejected.
Because the shared memory capacity is not
enough to increase the specified capacity, the
operation was rejected.
Because the specified THP V-VOL was used by
other software or was being formatted, the
operation was rejected.
Because the configuration of journal volumes is
being changed, the specified THP V-VOL
capacity cannot be expanded.
Because the raidcom extend ldev
command was executed with specifying the
-cylinder option to the THP V-VOL for the
open system, the operation was rejected.
The operation was rejected. Because the pages
capacity is sure to be exceeded of the depletion
threshold if the specified pages capacity is
reserved in the pool.
Solutions
Check the emulation type of the specified THP
V-VOL.
Specify a capacity so that the maximum number
of cache management devices will not be
exceeded.
Makes sure that the volume is a THP V-VOL.
To increase capacity, specify the correct
capacity that does not exceed the value
immediately below LDEV Capacity in the Expand
Virtual Volumes window. See the conditions for
increasing THP V-VOL capacity in
for increasing THP V-VOL capacity" (page
Re-execute the operation after a brief interval.
Confirm the value immediately below LDEV
Capacity in the Expand Virtual Volumes
window.
Wait until formatting of the specified volume is
finished, or see
Smart Tiers Z with other HP XP7 Storage
products" (page 64)
THP V-VOL is used with software in which that
the THP V-VOL capacity cannot be increased.
Re-execute the operation after the journal volume
configuration is changed.
Re-execute the raidcom extend ldev
command without specifying the -cylinder
option.
Increase the pool capacity and perform the
operation again.
"Error Detail Dialog Box" (page 210)
"Requirements
62).
"Using Thin Provisioning Z or
and confirm whether the
appears. The