Siemens SCALANCE X101-1 Operating Instructions Manual page 44

Scalance x-100 series
Hide thumbs Also See for SCALANCE X101-1:
Table of Contents

Advertisement

Technical specifications
7.2 SCALANCE X101-1LD
Technical specifications
Optical parameters
Cable type
Cable cross-section
Permitted cable length
Attenuation
Bending radius
Electrical data
Power supply
Signaling contact
Current consumption
Minimum rated current of the power
supply unit
Power loss at 24 VDC
Overvoltage protection at input
Permitted ambient conditions
Ambient temperature
Relative humidity
Operating altitude
Design, dimensions and weight
Immunity
Emission
Degree of protection
MTBF (EN/IEC 61709, 40 °C)
Housing material
Weight
Dimensions (W x H x D)
Installation options
44
Single mode glass FO cable
10/125 μm
0 to 26,000 m
≤ 0.5 dB/km at 1310 nm
13 dB max. permitted FO cable attenuation with 2 dB link power margin
once without tensile force
several times with tensile force
Voltage range
Rated voltage
Design
Design
Typical
Typical
During operation
During storage
During transportation
During operation
During operation
EN 61000-6-2 Class A
EN 61000-6-3
IP30
134 years
Basic housing
Front cover
550 g
40 x 125 x 124 mm
Mounting on a DIN rail
Mounting on an S7-300 standard rail
Wall mounting
100 mm
150 mm
18 to 32 VDC Safe Extra Low Voltage
(SELV)
24 VDC
4-terminal plug-in block
2-terminal plug-in block
120 mA
200 mA
3 W
PTC resettable fuse (0.5 A / 60 V)
-10 ℃ to +60 ℃
-40 ℃ to +80 ℃
-40 ℃ to +80 ℃
≤ 95 % no condensation
≤ 2,000 m above sea level at max. 56 ℃
ambient temperature
≤ 3,000 m above sea level at max. 50 ℃
ambient temperature
Die cast aluminum, powder coated
Polyphenylene ether + polystyrene
(PPE+PS plastic)
SCALANCE X-100 media converter
Operating Instructions, 04/2016, C79000-G8976-C346-02

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scalance x101-1ld

Table of Contents