Single Controller, Single Enclosure, Low Profile Sas - Dell SC8000 Deployment Manual

Compellent storage center
Table of Contents

Advertisement

Path
Chain 1: Side A 1 Connect the first controller port 1 to the first enclosure, top EMM, port A.
Chain 1: Side B 1 Connect the first controller port 3 to the last enclosure, bottom EMM, port B.
Note: The cabling illustrations in this chapter refer to enclosures as Enclosure 1, 
Enclosure 2, and so on. The numbers shown in the illustrations may not match the 
Index number assigned by the System Manager. Storage Center assigns an Index 
only after the system is powered up and at least one drive is assigned to a Disk 
Folder.

Single Controller, Single Enclosure, Low Profile SAS

This illustration shows an SC8000 controller cabled to a 6 Gb SAS enclosure using a low 
profile SAS IO card in a low profile card slot.
Figure 60. Single SC8000 Controller, Single SAS Enclosure, Low Profile SAS IO Card
Path
Chain 1: A Side
Chain 1: B Side
Dell Compellent
High-Level Steps
2 Connect the remaining enclosures in series from B port to A port using the top 
EMMs.
3 If the Storage Center has dual‐controllers, connect the last enclosure, top EMM, 
port B to the second controller, port 3.
2 Connect the remaining enclosures in series from A port to B port using the 
bottom EMM.
3 If the Storage Center has dual‐controllers, connect the top enclosure, bottom 
EMM, port A to the second controller, port 1.
3
1
2
4
A
A
Connections
Controller: slot 3, port 1 → Enclosure: top EMM, port A.
Controller: slot 3, port 3 → Enclosure: bottom EMM, port B.
Connect SC200/SC220 Enclosures
B
B
61

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents